11. AUTO CALIBRATION
- 125 -
1. Connect as Fig 11-2(RS232 serial cable is connected between COM port of PC and MON port of
TEST JIG, in general)
2. Set the Power Supply 4.0V
3. Set the 3
rd
, 4
th
of DIP SW ON state always
4. Press the Phone power key, if the Remote ON is used, 1
st
ON state
E. Procedure
1. Connect as Fig 11-2 (RS232 serial cable is connected between COM port of PC and MON port of
TEST JIG, in general.)
2. Run Hot_Kimchi.exe to start calibration.
3. From the Calibration Lib menu, Select F3000, then, Press APPLY!
LED Number Name Description
LED 1 Power Power is provided for Test Jig
LED 2 TA Indicate charging state of the phone battery
LED 3 UART Indicate data transfer state through the UART port
LED 4 MON Indicate data transfer state through the MON port
Table 11-4 LED Description