Do you have a question about the LG LA090HYV3 and is the answer not in the manual?
Energy Efficiency Ratio (EER) | 3.6 |
---|---|
HSPF | 10.0 |
Coefficient of Performance (COP) | 3.6 |
Voltage (V) | 220-240 V |
Power Supply | 1-phase, 50 Hz |
Defines symbols used in the manual for hazard classification.
Instructions for safe installation of the unit to prevent hazards.
Further safety instructions for unit installation to prevent hazards.
Safety precautions and guidelines for electrical wiring installation.
Safety instructions for operating the unit to prevent injury and damage.
Explains the model number coding system for single zone wall mount units.
Lists included parts and required field-provided parts for installation.
Details technical specifications for different unit models.
Provides electrical data and specifications for the units.
Guidelines for selecting the best location for the outdoor unit.
Specifies minimum clearance requirements for outdoor unit installation.
Instructions for safely rigging, lifting, and mounting the outdoor unit.
Details on mounting the outdoor unit, including concrete platform specs.
Specifies clearance requirements for indoor unit installation.
Instructions for mounting the indoor unit and its installation plate.
Addresses refrigerant safety and concentration limits in occupied spaces.
Guidelines for selecting and installing copper piping for the system.
Explains pipe expansion/contraction and methods to manage it.
Instructions for handling and storing piping materials to ensure cleanliness.
Guidelines for using elbows in refrigerant piping and their impact on length.
Best practices for routing refrigerant piping around obstacles.
Recommendations for using pipe sleeves at wall/floor penetrations.
Detailed procedures for flaring and brazing refrigerant connections.
Overview of refrigerant piping connections between indoor and outdoor units.
Specific installation considerations for different unit positioning.
Detailed steps for connecting refrigerant piping to the outdoor unit.
Detailed steps for connecting refrigerant piping to the indoor unit.
Installation instructions for the outdoor unit condensate drain hose.
Installation of the indoor unit condensate drain hose.
Instructions for bundling refrigerant piping, drain hose, and cables.
Guidelines for insulating refrigerant piping for safety and performance.
Safety guidelines and specifications for electrical system installation.
Details on connecting power and communication cables.
Information on wired and wireless remote controller connections.
Instructions for making electrical connections to the indoor unit.
Instructions for making electrical connections to the outdoor unit.
Procedure for performing leak and pressure tests on the refrigerant system.
Continues leak/pressure testing and details the deep evacuation procedure.
Details on deep evacuation and triple evacuation procedures for the system.
Step-by-step guide for triple evacuation of the refrigerant system.
Procedure for adding refrigerant trim charge based on piping length.
Steps to complete after leak tests and evacuation, including opening refrigerant lines.
Final steps for securing the indoor unit to the installation plate.
Instructions for reattaching the indoor unit's bottom panel.
Procedures for installing batteries, performing a test run, and evaluating performance.
Instructions for accessing installer modes like Cooling Only or Heating Only.
Procedure for pumping down the refrigerant system for servicing.
Overview of the LGMV software for system monitoring and diagnostics.
Using the LG SIMs app for system monitoring and troubleshooting.
Lists and explains error codes for indoor and outdoor units.
Guidelines addressing refrigerant safety and concentration limits.