10
REFRIGERANT PIPING
INSTALLATION OF OUT DOOR UNIT
Perform the work according to the Service
Manual or Installation Guide.
Select a location that satisfies the following
conditions. Install the unit firmly in place.
Select the following location
A place where the air conditioner can get good ventilation.
A place where it shall not annoy the neighbors.
A place where the unit shall be leveled and that can support the weight of unit and
withstand its vibrations.
Keep a maintenance space
* One side must be 90Cm for service.
Two of the remaining three sides
may be 30Cm.
Use two spanners when connect the
refrigerant pipe to the unit.
Make a bend with a radius as large as
possible.
Perform air purge with R-22 or vacuum
drying.
When piping work is finished, check all
joints.
Add refrigerant if piping is over 7.5m.
Above 70Cm
Above 30Cm
Outdoor unit
Above 30Cm Above 50Cm
Face of wall
Above 90Cm
*Above 90Cm
Above
90Cm
Above
90Cm
Capacity Addition volume
18K BTU/h 25 g/m
24K H/P 30 g/m
BTU/h C/O 25 g/m
30K BTU/h 50 g/m
36K BTU/h 40 g/m
42K/48K BTU/h 50 g/m
60K BTU/h
100 g/m
(LB-E6082CL)
60K BTU/h
60 g/m
(LB-E6081)