Ceiling Duct Conditioner
SVC MANUAL(Exploded View)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
MODEL:
LBNS3061BL
LBNS3062BL
LBNS3063BL
LBNS3064BL
LBNK3661BL
ABNH366KSB0
LBNK4261BL
LBNK4262BL
LBNK4263BL
LBNK4881BL
LBNK4882BL
LBNK4883BL
LBNH608RSS1
LBNH608RSS3
LBNM7280BL
LBNM7281BL
LBNM9080BL
LBNM9081BL
LBNM1081BL
LBUS3061BL
LBUS3062BL
LBUS3064BL
LBUK3660BL
ABUH366KSB0
LBUK4260BL
LBUK4262BL
LBUK4880BL
LBUK4882BL
LBUH608RSS3
LBUM7280BL
LBUM9080BL
LBU1081BL
Question and Answer IconNeed help?

Do you have a question about the LG LBUM7280BL and is the answer not in the manual?

LG LBUM7280BL Specifications

General IconGeneral
BrandLG
ModelLBUM7280BL
CategoryAir Conditioner
LanguageEnglish

Summary

Functions

Remote Controller

Explains the operation and features of the remote controller for the unit.

Product Specifications (Cooling & Heating)

Dimensions

1. Indoor

Detailed dimensions and mounting hole locations for the indoor unit.

2. Outdoor Unit

Provides dimensional data and types for the outdoor unit.

Refrigeration Cycle Diagram

Wiring Diagram

Operation Details

1. Time Delay safety Control

Details the safety controls for compressor and 4-way valve operation.

2. Soft-Dry Operation

Describes the automatic fan speed adjustment for the Soft-Dry mode.

3. Cooling Mode Operation

Explains the unit's operation during cooling mode based on temperature settings.

4. Heating Mode Operation (Except Cooling Model)

Describes heating mode operation, including fan and compressor control.

5. Hot-Start Control

Explains the control mechanism for starting heating operation after defrost.

6. Defrost Control

Details the conditions and duration for defrost operation in heating mode.

7. Self-diagnosis Function

Explains error codes displayed on the remote controller and their meanings.

Installation of Indoor, Outdoor Unit

1. Selection of the best location

Criteria for choosing suitable installation sites for indoor and outdoor units.

2. Outdoor unit

Recommendations for outdoor unit placement, considering environmental factors.

3. Piping length and the elevation

Specifies maximum allowable piping length and elevation differences.

2. Ceiling dimension and hanging bolt location

Instructions for mounting the unit to the ceiling with suspension bolts.

3. Remote Controller Installation

Guidelines for installing the wired remote controller, including wiring.

Connecting Cables between Indoor Unit and Outdoor Unit

1) Connecting cables to the Indoor Unit

Details on connecting wires to the indoor unit's control board.

2) Clamping of cables

Procedures for securely clamping power and connecting cables.

ELECTRICAL WIRING

Covers electrical wiring requirements, circuit breaker capacity, and connection procedures.

Connecting Pipes to the Indoor Unit

1) Cut the pipes and the cable.

Instructions for cutting pipes and cables to the correct length.

2) Burrs removal

Procedure for removing burrs from cut pipe ends to ensure proper connection.

3) Putting nut on

Guidance on placing flare nuts onto the pipe before flaring.

4) Flaring work

Detailed steps for performing correct flaring work on copper pipes.

5) Check

How to inspect the quality of the flared pipe connection.

Piping Connection

Steps for forming and connecting refrigerant piping, ensuring no leaks.

Vacuum drying

Procedure for removing air and moisture from the refrigeration system.

CAUTION

Important notes on indoor unit declination for drainage and pipe insulation thickness.

INSULATION, OTHERS

Guidance on insulating joints and tubes, and overall thermal insulation requirements.

Test running

PRECAUTIONS IN TEST RUN

Essential safety checks and operational guidelines before starting the unit.

2) Connection of power supply

Steps for connecting the unit to the power supply and operating it.

3) Evaluation of the performance

Methods for evaluating unit performance by measuring air temperatures.

Optional Operation

1) Two Thermistor System

Configuration options for controlling room temperature using thermistors.

2) Group Control(Optional Wiring)

Instructions for connecting multiple units for group control operation.

Cycle

1. Installation (Connecting the piping between indoor and outdoor unit)

Step-by-step guide to connecting refrigerant lines and purging air.

2. Disconnection (on moving)

Procedure for safely disconnecting refrigerant piping when moving the unit.

3. Gas Charging

Detailed steps for charging the system with refrigerant after evacuation.

Cycle Troubleshooting Guide

Electronic Parts Troubleshooting Guide

Possible Trouble 2 : The indoor fan does not operate.

Troubleshooting steps if the indoor fan fails to operate.

Possible Trouble 3 : Ineffective Heating

Diagnostic steps for addressing poor heating performance.

Possible Trouble 4 : Wired remote controller does not operate.

Troubleshooting steps for a non-functional wired remote controller.

Electronic control device

Exploded View and Replacement Parts List

1. Indoor Unit

Exploded view and parts list for the indoor unit model LBNS3061BL.