- 41 -
3) Abnormal Refrigerator Sensor (R)
1
Check for loose connection in CON7
No Checking flow Result & SVC Action
Result SVC Action
Firmly plugged Go to step 2
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step 2
NO: explain to customer.
2
1-. Unplug connector from CON7.
2-. Check resistance value between
wires white to white.
Result SVC Action
7.15~ 40KÙ Replace Main PCB (See NOTE1)
Other Value Replace Sensor.
0Ù or open Go to step #3
NOTE 1: Be sure that resistance value measurement
match with real compartment temperature (Refer to R -
Sensor chart). Else, consider it as “Other Value”
Condition.
3
1-. Remove cover from Refrigerator
Sensor.
Result SVC Action
Open Circuit Go to step #4
0Ù Replace Refrigerator unit.
2-. Pull the Sensor, then cut the wires.
3-. Strip the wire ends, and keep
separated.
4-. Check resistance value between blue
& blue wires.
*Representative picture.
NOTE: Keep wire ends separated during measurement.