- 62 -
3) Refrigerator LED Lamp not working
1
Check for loose connection in CON6
No Checking flow Result & SVC Action
2
Check Voltage between Red and Black
wires.
Result SVC Action
11~12VDC Go to step #3
Other Value Replace Main PCB.
Result SVC Action
Firmly plugged Go to step #2
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #2
NO: explain to customer.
3
Check for loose connection in harness
joint, located in Case Main PCB.
Result SVC Action
Firmly plugged Go to step #4
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #4
NO: explain to customer.