- 76-
4
1-. Remove bottom basket from Left
refrigerator door.
No Checking flow Result & SVC Action
5
Result SVC Action
110~120VAC Go to step #6
0-10VAC Replace Left Refrigerator Door.
1-. Check for voltage between yellow
and black wires.
2-. Remove Cover.
3-. Check for loose connection
Result SVC Action
Loose Connection Plug correctly, check again
Firmly connected Go to step #5