- 27 -
8-6 Freezer Fan Error (Er FF)
No
1
2
Checking flow
Reset the unit and 
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the air
flow.
※ While 
 
an 
 
error 
 
code 
 
is 
 
displayed, 
 
the
fan 
 
is 
 
not 
 
working.
3 Check the Fan motor. 
Rotate fan using your hand.
It feel sticky, change the motor.
(cause of ice or rust inside of motor)
4 Check the Fan motor voltage. 
Result & SVC Action
Below 7 V
0 or 5 V
(2) ~ (3)
(1) ~ (3)
Change the PCB
Change the motor
Point Result SVC Action
Status
No windy
Windy
SVC Action
Go to 3
Go to 4
<CON7>
(1)Pin8, (2)Pin10, (3)Pin12