- 49 -
11-6 AC Motor ASSEMBLY
Function The In-door motor of AC motor assembly pushes ices to the dispenser.
How to
Measure
< In-door Motor > < In-door Motor >
Standard
Geared Motor
Test Points
(1) to (2)
Result
20 ~ 42
Cube Solenoid
Test Points
(1) to (3)
Result
20 ~ 42
Take out the male
housing from
female housing
Measure the
resistance between
(1) and (2)
Check the resistance between connectors (In-door motor 1, 2) and
(In-door motor 1, 3). It means check whether or not applying an
Electric current. If there is resistance, it means the geared motor or
solenoid is not inferiority
(1)
(2)
(3)
(1)
1
2
Take out the male
housing from
female housing
Measure the
resistance between
(1) and (3)
1
2

Other manuals for LG LFX25974 Series