EasyManua.ls Logo

LG LFX25974 Series - Page 57

LG LFX25974 Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 57 -
B5. LED blinks seven times, then repeats (IPM Fault: A & E Inverters)
Protection Logic
Blink BlinkBlink Blink Blink Blink Blink OFF
Protection
logic
Check B
Blink 7 times
(Lock Piston Trip) Check B5
Compressor
Doesn’t work
Y
N
Repeat
Check Procedure
Replace
Drive PCB
N
Y
Check IPM
visual inspection
(turn off)
Short
Test
Point A
Power
Reset
Compressor
Damage
Check C3
Replace
Compressor
NG
Y
Modify
- Purpose: Prevent high current due to IPM Short
- Cause: Damaged IPM (Dead Short)
- Test for a dead short at Point A with a VOM.
- Logic: Compressor is forced off and tries to restart in 20 minutes.
A

Other manuals for LG LFX25974 Series

Related product manuals