3. TECHNICAL BRIEF
Copyright © 2012 LG Electronics. Inc. All right reserved.
O nly for training and service purposes
LGE Internal Use Only
18
Deep Discharge Lockout (DDLO)
PMU will enter the deep discharge lockout (DDLO) state when the battery voltage falls below 2.5V. In this state,
the VRTC LDO will be shutdown.
Reset
The PMU contains a reset control circuit which will take effects at both power-up and power-down. The “RESETB”
pin is held low in the beginning of the power-up and returns high after the pre-determined delay time. At
power-off, the “RESETB” pin will return low immediately without any delay.
3. TECHNICAL BRIEF
Figure.3.2.3 Power-on/off Control Sequence