EasyManua.ls Logo

LG LMN079HVT User Manual

LG LMN079HVT
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MULTI
F
MAX
MULTI
F
OUTDOOR UNIT
INSTALLATION MANUAL
Multi-Zone Heat Pump Systems
1.5 to 5 Tons
Dual and Tri-Zone
Multi F
Quad-Zone
Multi F
Eight-Zone
Multi F MAX
Question and Answer IconNeed help?

Do you have a question about the LG LMN079HVT and is the answer not in the manual?

LG LMN079HVT Specifications

General IconGeneral
ModelLMN079HVT
SEER22
HSPF10
RefrigerantR410A
Indoor Unit Weight17.6 lbs
TypeMini Split
Power Supply1 Phase, 60Hz
Noise Level (Indoor)19 dB
Operating Temperature (Heating)75°F

Summary

SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS (continued)

Wiring Safety

Crucial safety measures for electrical connections.

ELECTRICAL DATA

Multi F and Multi F MAX Outdoor Units Electrical Data

Electrical parameters for different models.

GENERAL INSTALLATION GUIDELINES

Selecting the Best Location for the Outdoor Unit

Criteria for optimal outdoor unit placement.

GENERAL INSTALLATION GUIDELINES (continued)

Rigging Instructions / Platform Instructions for Outdoor Unit

Rigging and Lifting Instructions

Procedures for safely rigging and lifting the unit.

Location for Multi F MAX Branch Distribution Units

Piping Preparation

Creating a Flare Fitting

Procedure for making proper flare connections.

Piping Preparation (continued)

REFRIGERANT PIPING CONNECTIONS

Piping Length and Elevation Limitations

Maximum allowable pipe lengths and elevation differences.

REFRIGERANT PIPING CONNECTIONS (continued)

Multi F MAX Piping Length and Elevation Limitations

Specific length and elevation limits for MAX systems.

REFRIGERANT PIPING PREPARATION

REFRIGERANT PIPING PREPARATION (continued)

Leak Test and Vacuum Procedures

Essential steps for system leak testing and evacuation.

Leak Test Procedure, continued.

Continuation of leak test steps and observations.

Vacuum Procedure

Step-by-step process for system vacuum evacuation.

Leak Test

Procedure for testing the system for leaks.

Essential Points for Leak Testing

Key considerations for successful leak testing.

Leak Test Procedure

Detailed steps for performing the leak test.

REFRIGERANT CHARGE

Multi F Systems Refrigerant Charge Calculation

Formula and data for calculating refrigerant charge for Multi F.

REFRIGERANT CHARGE (continued)

Multi F MAX Systems Refrigerant Charge Calculation

Formula and data for calculating refrigerant charge for Multi F MAX.

Charging the Refrigerant

Procedure for safely charging the system with refrigerant.

WIRING

Power Supply and Wiring Specifications

Requirements for power supply and wiring.

WIRING (continued)

Power Wiring and Communications Cable Connections

Connecting Power and Communications Cables to the Outdoor Unit

Step-by-step guide for connecting cables to the outdoor unit.

Power Wiring and Communications Cable Connections (continued)

Connecting Power and Communications Cables to the Outdoor Unit, continued.

Additional steps for connecting cables to the outdoor unit.

TEST RUN

Test Run Overview

General steps for performing a system test run.

Test Run Procedure

Detailed steps for operating and checking the system.

DIP SWITCH SETTINGS

Outdoor Unit DIP Switch Settings

Overview and function of outdoor unit DIP switches.

DIP SWITCH SETTINGS (continued)

TROUBLESHOOTING

Self Diagnosis Functions

Utilizing built-in diagnostic capabilities.

LG Monitoring View (LGMV) Diagnostic Software

Using LGMV software for system monitoring and troubleshooting.

TROUBLESHOOTING (continued)

LG Monitoring View (LGMV) Software and Cable - Continued

Further details on LGMV software features and data.

Error Codes Overview

Introduction to system error codes.

Error Codes

Troubleshooting Using Error Codes

How to interpret and use error codes for diagnosis.

CAUTIONS FOR REFRIGERANT LEAKS

Refrigerant Leak Introduction and Safety

Overview of refrigerant safety standards and concentration limits.

MULTI F REFRIGERANT CHARGE WORKSHEET

Multi F Refrigerant Charge Calculation Formula

Formula for calculating additional refrigerant charge.

Multi F Outdoor Unit Piping Specifications

Piping data needed for charge calculation.

MULTI F MAX REFRIGERANT CHARGE WORKSHEET

Multi F MAX Refrigerant Charge Calculation Formula

Formula for calculating additional refrigerant charge for MAX systems.

Multi F MAX Outdoor Unit Piping Specifications

Piping data for MAX system charge calculation.

Related product manuals