8-3 RESISTANCE SPECIFICATION OF SENSOR
• The resistance of the SENSOR has a ±5% tolerance.
• Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE
RESISTANCE OF FREEZER/ICING
RESISTANCE OF REFRIGERATOR &
SENSOR
DEFROST SENSOR & ROOM SENSOR
- 20 ˚C 22.3 K 77 K
- 15 ˚C 16.9 K 60 K
- 10 ˚C 13.0 K 47.3 K
- 5 ˚C 10.1 K 38.4 K
0 ˚C 7.8 K 30 K
+ 5 ˚C 6.2 K 24.1 K
+ 10 ˚C 4.9 K 19.5 K
+ 15 ˚C 3.9 K 15.9 K
+ 20 ˚C 3.1 K 13 K
+ 25 ˚C 2.5 K 11 K
+ 30 ˚C 2.0 K 8.9 K
+ 40 ˚C 1.4 K 6.2 K
+ 50 ˚C 0.8 K 4.3 K
www.Appliantology.org