What to do per LED Blinking and Trip protection Logic
2. Stroke Trip and LED Blinking 2 times (Stroke Trip)
Blink OFF Blink OFFBlink Blink
→ Purpose : Protection piston crash by abnormally large stroke.
→ Case 1. Do not operate COMP : Harness connection failure between the PCB, COMP, Capacitor.
→ Case 2. Do operate COMP intermittently : Condenser Fan or Freezer Fan Error.
System Error like water-clogging, capillary-clogging,
Refrigerant-leakage
→ Logic : After the COMP off every 1 minute restart COMP
PCBA output
> 60[V] ?
N
LED 2
Blinks
Operate
COMP?
Y
Harness
Wiring?
Y
Repair
Harness
N
LED 2
Blinks
Check
COMP
Check
Cycle leakage
About 5min
Reset
Test Mode
1 Input
Replace PCB
Y
N
- 84 -
Copyright © 2018 LG Electronics Inc. All rights
reserved. Only training and service purposes.