EasyManuals Logo

LG LRFCS29D6 Series Service Manual

LG LRFCS29D6 Series
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
-28-
Symptom Check Point
1. IS E 1. Check for a loose connection
2. Check Sensor Resistance
Resistance [
CON5
15
th
pin ~ 17
th
pin
Short 0
Open OFF
Other Normal
8-3. Icing Sensor Error (IS E)
CON5
15
th
pin ~ 17
th
pin
Resistance [
-22ºF / -30ºC 40k
-13ºF / -25ºC 30k
-4ºF / -20ºC 23k
-13ºF / -25ºC 17k
14ºF / -10ºC 13k
23ºF / -5ºC 10k
32ºF / 0ºC 8k
CON6
CON1
CON201
CON4
CON5
CON7
CON2 CON3

Other manuals for LG LRFCS29D6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG LRFCS29D6 Series and is the answer not in the manual?

LG LRFCS29D6 Series Specifications

General IconGeneral
BrandLG
ModelLRFCS29D6 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals