EasyManua.ls Logo

LG LRSC26911SW - Page 45

LG LRSC26911SW
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensor resistance characteristics table
u Resistance value allowance of sensor is ±5%.
u When measuring the resistance value of the sensor, allow the temperature of that sensor to stabilize for at least 3 minutes
before measuring. This delay is necessary because of the sense speed relationship.
u Use a digital tester to measure the resistance. An analog tester has too great a margin of error.
u Resistance of the cold storage sensor 1 and 2 should be measured with a digital tester after separating CON8 of the
PWB ASSEMBLY and the MAIN part.
u Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.
EXPLANATION FOR MICOM CIRCUIT
- 45 -
Measuring Temperature (°C) Freezing Sensor
Cold storage sensor 1&2
Frost removal sensor, Outside sensor
-20 °C (-4 °F) 22.3 k 77 k
-15 °C (5 °F) 16.9 k 60 k
-10 °C (14 °F) 13.0 k 47.3 k
-5 °C (23 °F) 10.1 k 38.4 k
0 °C (32 °F) 7.8 k 30 k
+5 °C (41 °F) 6.2 k 24.1 k
+10 °C (50 °F) 4.9 k 19.5 k
+15 °C (59 °F) 3.9 k 15.9 k
+20 °C (68 °F) 3.1 k 13 k
+25 °C (77 °F) 2.5 k 11 k
+30 °C (86 °F) 2.0 k 8.9 k
+40 °C (104 °F) 1.4 k 6.2 k
+50 °C (122 °F) 0.8 k 4.3 k

Related product manuals