2. Compensation circuit for temperature at freezer
(1) GR-L267BV(T)RA (2) GR-L267BV(T,S)PA
u This circuit allows adjustment of the set temperature for compensation by changing jumpers at locations JCR1~JCR4.
EXPLANATION FOR MICOM CIRCUIT
- 49 -
Compensation Compensation
for weak-cold for over-cold
Temperature compensation value
Remarks
JCR3 JCR4 JCR1 JCR2
at refrigerator
0 °C (In shipment from factory)
CUT -1 °C [-1.8 °F]
CUT -1 °C [-1.8 °F]
CUT +1 °C [+1.8 °F]
CUT +1 °C [+1.8 °F]
CUT CUT -2 °C [-3.6 °F]
CUT CUT +2 °C [+3.6 °F]
CUT CUT 0 °C [0 °F]
CUT CUT 0 °C [0 °F]
CUT CUT 0 °C [0 °F]
CUT CUT 0 °C [0 °F]
CUT CUT CUT -1 °C [-1.8 °F]
CUT CUT CUT +1 °C [+1.8 °F]
CUT CUT CUT CUT 0 °C [0 °F]
Temperature compensation in CUT
JCR1 +1 °C [+1.8 °F]
+2 °C [+3.6 °F]
JCR2 +1 °C [+1.8 °F]
JCR3 -1 °C [-1.8 °F]
-2 °C [-3.6 °F]
JCR4 -1 °C [-1.8 °F]