EasyManua.ls Logo

LG LS-C07 Series - User Manual

LG LS-C07 Series
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Room Air Conditioner
OWNER'S MANUAL
• Please read carefully and thoroughly this manual
before operating this unit.
• Contact the authorized SVC man for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The appliance is not intended for use by young
children or infirm persons without supervision.
• Young children should be supervised to ensure that
they do not play with the appliance.
Prior to installation, this air-conditioning
unit must be submitted for approval by the utility
service which provides electricity (EN 61000-3 Norm).
MODELS: LS-C07_Series
LS-H07_Series
LS-C09_Series
LS-H09_Series
LS-C12_Series
LS-H12_Series
AS-C07_Series
AS-H07_Series
AS-C09_Series
AS-H09_Series
AS-C12_Series
AS-H12_Series
C07L_Series
C07A_Series
C09L_Series
C09A_Series
C12L_Series
C12A_Series
ENGLISH INDONESIA
Registration No.:
338/PDN/MG/VI/2003
Question and Answer IconNeed help?

Do you have a question about the LG LS-C07 Series and is the answer not in the manual?

Overview

This document is an owner's manual for LG Room Air Conditioners, providing comprehensive information on their operation, maintenance, and troubleshooting. The manual is available in both English and Indonesian, as indicated by the labels on the right side of the cover page.

Function Description

The LG Room Air Conditioner is designed to provide various climate control functions for indoor spaces. Its primary functions include:

  • Cooling Mode: Reduces the room temperature to a desired level.
  • Auto Operation Mode: Automatically adjusts cooling based on the ambient temperature.
  • Healthy Dehumidification Mode: Reduces humidity in the room while maintaining a comfortable temperature.
  • Heating Mode (Heat Pump Model Only): Increases the room temperature.
  • Defrost Mode: Operates to defrost the outdoor unit when necessary, typically during heating operation in cold weather.
  • Air Circulation Mode: Circulates air without cooling or heating.
  • Sleep Mode: Optimizes temperature and fan speed for comfortable sleep.
  • Timer Mode: Allows users to set specific times for the unit to turn on or off.
  • Auto Cleaning Mode: Automatically cleans the indoor unit to prevent mold and odors.
  • Jet Cool Mode: Provides rapid cooling for a short period (30 minutes) at super high fan speed.
  • PLASMA Purification Operation (Optional): Utilizes PLASMA technology for air purification, removing impurities and allergens from the air.
  • 2nd F Operation: A special function, details of which are further explained in the manual.
  • Vertical Airflow Direction Control: Adjusts the up/down airflow direction.
  • Horizontal Airflow Direction Control (Optional): Adjusts the left/right airflow direction.
  • Forced Operation: Allows the unit to operate even if the remote control is unavailable or malfunctioning, using a power button on the indoor unit.
  • Auto Restart: Automatically restarts the unit with previous settings after a power failure.

Important Technical Specifications

While specific technical specifications like power consumption, cooling capacity, or dimensions are not explicitly listed on the cover or in the provided snippets, the manual covers a range of models, including:

  • LS-C07_Series, LS-H07_Series, LS-C09_Series, LS-H09_Series, LS-C12_Series, LS-H12_Series: These appear to be standard split-type air conditioner models, with numbers likely indicating cooling capacity (e.g., 7,000, 9,000, 12,000 BTU/h). The 'C' might denote cooling-only models, and 'H' might denote heat pump models.
  • AS-C07_Series, AS-H07_Series, AS-C09_Series, AS-H09_Series, AS-C12_Series, AS-H12_Series: Similar to the LS series, these could represent different design or feature sets, or perhaps a different product line with similar capacity indications.
  • C07L_Series, C07A_Series, C09L_Series, C09A_Series, C12L_Series, C12A_Series: These might refer to specific sub-models or variations within the C07, C09, and C12 capacity ranges.

The manual also mentions the use of AAA (1.5volt) batteries for the remote control. The registration number for the device is 338/PDN/MG/VI/2003, indicating a specific regulatory approval.

Usage Features

The LG Room Air Conditioner is designed for user-friendly operation, primarily through a remote control with a clear display.

  • Remote Control: The primary interface for controlling the unit. It features buttons for Start/Stop, Mode Selection (Cooling, Auto, Healthy Dehumidification, Heating), Temperature Adjustment (up/down arrows), Fan Speed (Low, Medium, High, CHAOS), Timer, Sleep, Jet Cool, PLASMA, and 2nd F functions. The remote control display shows the selected mode, temperature, fan speed, and other indicators.
  • Signal Receptor: The indoor unit has a signal receptor that receives commands from the remote control. Icons on the unit illuminate to indicate the active operation.
  • Temperature Setting: Users can adjust the desired room temperature in 1°C increments.
  • Fan Speed Control: Multiple fan speed settings are available, including Low, Medium, High, and CHAOS. The CHAOS logic provides a more natural breeze by automatically changing fan speed.
  • Timer Functions: Delay Start/Pre-Set Stop functions allow users to program the unit to turn on or off at specific times, with options for 1 to 7 hours.
  • Child Safety: The manual emphasizes that the appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
  • Installation: The manual provides instructions for installation and recommends contacting an authorized SVC man for repair or maintenance.
  • Display Luminosity: The display luminosity can be adjusted (dark or bright) using the remote control.

Maintenance Features

Proper maintenance is crucial for the longevity and efficient operation of the air conditioner. The manual outlines several key maintenance procedures:

  • Indoor Unit Cleaning:
    • Front Panel: Can be opened to access internal components for cleaning.
    • Air Filters: Should be cleaned regularly (recommended every 2 weeks, or at least once every two weeks) to maintain airflow and efficiency. The manual provides steps for removing, cleaning (with a vacuum cleaner or warm, soapy water, or lukewarm water for stubborn dirt), drying, and reinstalling the filters.
    • PLASMA Filter (if applicable): Should be cleaned every 1-2 hours using neutral detergent and dried in the shade for a day. The manual provides steps for removing, cleaning, and reinstalling the PLASMA filter.
    • Heat Exchanger Coils and Panel Vents: Should be checked regularly (about 3 months) for dirt or soot. If clogged, they can be professionally steam cleaned.
    • Auto Clean Function: The unit operates a clean function automatically when this feature is activated.
  • Outdoor Unit Cleaning:
    • Heat Exchanger Coils and Panel Vents: Similar to the indoor unit, these should be checked regularly (about 3 months) and cleaned if clogged.
  • Long-Term Storage: When the air conditioner is not going to be used for a long time, the manual advises operating it in Air Circulation mode for 2 to 3 hours to dry out internal mechanisms. The air filter should be cleaned, and the circuit breaker should be turned off. Batteries should be removed from the remote control.
  • Pre-Call Service Checks: The manual includes a troubleshooting guide to help users identify and resolve common issues before calling for service, such as checking batteries, circuit breakers, and filter cleanliness.
  • Safety Precautions: The manual highlights several safety warnings, including ventilating before operation, not disassembling or modifying products, cleaning the air conditioner with water, and avoiding strong detergents or hot wax. It also warns against touching metal parts when removing the filter, and advises turning off the power and breaker before cleaning.

The manual emphasizes that maintenance should be performed by an authorized service technician for complex issues.

LG LS-C07 Series Specifications

General IconGeneral
BrandLG
ModelLS-C07 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals