- Refrigerator Sensor Error
1
No Checking Result and SVC countermeasure
Result SVC Support
Connected
Go to step 2.
Loose
2
0
Short
Go to step 3.
OFF Open
Other Normal
3
Check if there’s a connector loose on CON8.
0
Short
OFF Open
Otro Valor Normal
37
Connect firmly and check again.
Is there a problem?
Yes: Go to step 2.
No: Explain to customer.
Unplugged the refrigerator and all the PCB
connectors, check the resistance between
white wires for CON8.
Check temperature and resistance
(see chart of section 7-2).
Go to step 4.
Change harness from multi duct,
if it’s necessary.
Result SVC Support
Result
SVC Support
1. Check temperature and resistance
(see chart of section 7-2).
2. Place multi duct in its original
position.
3. Go to step 4.
Remove multi duct and check the resistance
between white wires of connector.
Image represents error
on display