Do you have a question about the LG LV181HV4 and is the answer not in the manual?
Explanation of warning symbols and their meaning for safe operation.
Safety precautions and warnings specific to the installation process.
Critical safety guidelines and warnings for electrical wiring installation.
Safety precautions and warnings for operating the air conditioning unit.
Explanation of the model naming convention and its components.
Detailed technical specifications for the vertical air handling units.
Electrical data and ratings for outdoor units.
Guidelines for choosing the optimal installation site for the unit.
Specific considerations for installing units in coastal environments.
Minimum spacing requirements for adequate airflow and service access.
Safe procedures for handling, rigging, and lifting the outdoor unit.
Minimum space requirements for indoor unit installation and service.
Guidelines and best practices for installing air ductwork.
Guidelines for refrigerant safety and maximum allowable concentration.
Limits for refrigerant piping length and elevation differences.
Guidance on selecting appropriate copper piping for the system.
Managing thermal expansion and contraction of refrigerant piping.
Proper methods and precautions for handling refrigerant piping.
Emphasis on using specified pipe sizes and avoiding substitutions.
Requirements and guidelines for properly supporting refrigerant piping.
Guidelines for installing refrigerant piping underground.
Step-by-step guide for performing flared connections.
Best practices and safety precautions for brazing refrigerant lines.
General approach and overview of refrigerant piping connections.
Methods for bundling refrigerant pipes and cables correctly.
Procedure for connecting refrigerant piping to the outdoor unit.
Procedure for connecting refrigerant piping to the indoor unit.
Guidelines for installing and routing the condensate drain hose.
Requirements for proper insulation of refrigerant piping.
Minimum wall thickness requirements for EPDM insulation.
General safety precautions for electrical system installation.
Guidelines for power wiring connections and best practices.
Specifications for communication/power cables between units.
Instructions for installing wired wall controllers.
Default settings for External Static Pressure (ESP).
Detailed steps for connecting wiring to the indoor unit.
Detailed steps for connecting wiring to the outdoor unit.
Configuration settings for NJ/NK chassis DIP switches.
Procedure for performing a triple leak and pressure test.
Steps for evacuating the refrigerant system to a specific micron level.
Procedure for adding refrigerant charge and performing a test run.
Procedure for pump down and setting the unit to cooling only mode.
Using the SIMs app for system monitoring and self-diagnosis.
Understanding and interpreting error codes for troubleshooting.
Safety information and calculations related to refrigerant leaks.
Checklist items for initial component installation.
Checklist items for refrigerant piping and insulation installation.
Checklist items for condensate drain system installation.
| Cooling Capacity | 18, 000 BTU/h |
|---|---|
| Heating Capacity | 20, 000 BTU/h |
| Airflow | 1, 100 CFM |
| Refrigerant Type | R410A |
| Energy Efficiency Ratio (EER) | 11.5 |
| Weight | 24.3 lbs |
| Power Supply | 208-230V, 60Hz, 1 Phase |