EasyManua.ls Logo

LG Multi-Inverter Type - Page 76

LG Multi-Inverter Type
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Trouble Shooting
- 75 -
Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Check Point
1. Check the Input Voltage (L–N 220V±10%)
2. Check Input Voltage Sensor output voltage (2.5Vdc±10%)
Is Inverter PCB Normal?
No
Replace inverter PCB assembly
Is input voltage normal ?
No
Check L~N Voltage is 220V±15%
Yes
< Input Power Source Check Point >
Recheck power and
installation condition
Yes
Error Diagnosis and Countermeasure Flow Chart
40
C/T
Sensor Error
• Initial current error
Malfunction of current detection circuit.
(Open / Short)
Check CT Sensor output voltage :
2.5Vdc ±5%
Display
code
Title Cause of error Check point & Normal condition

Related product manuals