EasyManua.ls Logo

LG Multi-Inverter - Self-Diagnosis Function

LG Multi-Inverter
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 46 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
4. Trouble Shooting
1. Self-diagnosis Function
1.1 Error Indicator (Indoor)
The function is to self-diagnosis air conditioner and express the troubles if there is any trouble.
Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit control
board.
If more than two troubles occur simultaneously, lower number of error code is first displayed.
After error occurs, if error is released, error LED is also released simultaneously.
1 Time 1 Time 1 Time
2 Times2 Times2 Times
10 digit
LED
1 digit
LED
1 Sec.
2 Sec. 2 Sec.
1 Sec.
1 Sec.
1 digit 10 digit
Ex) Error 21 (DC Peak)
1.2 Indoor Error
Case of errorContents
Error
code
Open / ShortOutlet pipe sensor06
Different operation modeDifferent operation mode07
Communication Poorly
Float switch Open
Communication Poorly
Open / Short
Open / ShortAir sensor (open/short)01
Inlet pipe sensor02
Communication(Indoor Wired R/Control)03
Drain pump/ Float switch04
Communication(Indoor Outdoor)05
Off