- 4 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Type
Model Unit
Cooling Capacity kW
kcal/h
Btu/h
Heating Capacity kW
kcal/h
Btu/h
Casing
Dimensions Body mm
(WxDxH) inch
Front Panel mm
inch
Coil Rows x Columns x FPI
Face Area m
2
Fan Type
Motor Outputx Number W
Running Current A
Air Flow Rate(H/M/L) CMM
cfm
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Pipe Liquid Side mm(inch)
Connections Gas Side mm(inch)
Drain Pipe(Internal Dia.) mm
Net Weight Body kg(lbs)
Noise Level (Sound Press, 1.5m, H/M/L) dB(A)
Power Supply
Ø, V, Hz
Refrigerant Control
Power cord
Transmission cable
Panel Color
Panel Name(Acc'y)
Elevaion Grill(Acc'y)
4 Way Ceiling Cassette
ARNU24GTP*2 ARNU28GTP*2 ARNU36GTN*2
7.1 8.2 10.6
6,100 7,100 9,100
24,200 28,000 36,200
8.0 9.2 11.9
6,900 8,000 10,200
27,300 31,500 40,600
Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
840 x 840 x 204 840 x 840 x 204 840 x 840 x 246
33.0x33.0x8.0 33.0x33.0x8.0 33.0x33.0x9.7
950x950x30 950x950x30 950x950x30
37.4x37.4x1.2 37.4x37.4x1.2 37.4x37.4x1.2
2 x 8 x 19 2 x 8 x 19 2x10x19
0.40 0.40 0.57
Turbo Fan Turbo Fan Turbo Fan
30 30 135
0.15 0.15 0.56
17/15/13 19/16/14 25/21/19
600/529/459 671/565/494 883/742/671
Direct Direct Direct
BLDC BLDC BLDC
Microprocessor, Thermostat for cooling and heating
Foamed polystrene Foamed polystrene Foamed polystrene
Fuse Fuse Fuse
Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
25.0 25.0 25.0
20.8(45.8) 20.8(45.8) 23.5(51.8)
38/35/31 39/38/32 43/40/39
1, 220~240, 50 1, 220~240, 50 1, 220~240, 50
1, 220, 60 1, 220, 60 1, 220, 60
EEV EEV EEV
CV2.0 X 3C CV2.0 X 3C CV2.0 X 3C
CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C
Morning fog Morning fog Morning fog
PT-UMC
PT-UME
* Model Name
A:Basic, C:Plasma
Notes:-
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60