Installation Manual 65
ENGLISH
Electrical Wiring
Group Number setting
Group Number setting for Indoor Units
Confirm the power of whole system(Indoor Unit, Outside Unit) is OFF, otherwise turn off.
The transmission lines connected to CEN terminal should be connected to central control of Outside unti with
care for their polarity( A A, B B )
Turn the whole system on.
Set the group and Indoor Unit number with a wired remote control.
To control several sets of Indoor Units into a group, set the group ID from 0 to F for this purpose.
Terminal block on the main PCB
SODU IDU CEN DRY1 DRY2
B
A
B(D) A(C)
GND 12V
B
A
BA
Group recognizing the simple central controller
No.0 group (00~0F)
No.1 group (10~1F)
No.2 group (20~2F)
No.3 group (30~3F)
No.4 group (40~4F)
No.5 group (50~5F)
No.6 group (60~6F)
No.7 group (70~7F)
No.8 group (80~8F)
No.9 group (90~9F)
No. A group (A0~AF)
No. B group (B0~BF)
No. C group (C0~CF)
No. D group (D0~DF)
No. E group (E0~EF)
No. F group (F0~FF)
Outside Units