PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
Checking point Display
None LqC 1
1 time
Check the version and code of
machine.
ELECTRIC TYPE : P3 OE
GAS TYPE : P3 Og
Version and code of machine (All LED on)
Display P3:OE or P3:Og and gU:XX alternately. XX is the
version number.
2 time PDA CHECK Ir--
3 time Motor runs. Measured moisture value (70~239)
4 time
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
GAS TYPE: GAS valve runs.
Motor + Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
5 time
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
GAS TYPE: GAS valve runs.
Motor+Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
6 time
LED & KEY CHECK
Press High Temp. button.
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button
Version and code of machine
7 time Test ends. LqC1
During check, if the
door is open.
Door switch
(Motor & Heater Off, Buzzer beeps
seven times)
dE
(The door is open. Please close the door completely)
During check, if the
door is closed
Test goes back at step 2.
(Motor on & Heater Off )
Measured moisture value (70~239)
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
NOTE
MFL62512875_150414.indd 39 2015.4.14 9:44:2 AM