PROGRAMMING MODE
■ Collect Mode Data lists
No.
Abbreviation
Meaning Description
23 Itnr Interval No Runs Itnr is not available in dryer.
24 Ittb Interval Trouble Cycles Money inserted, but no run.
25 ItPd Interval Power Downs No money, but ran.
26 Itdd
Interval Unauthorized Service Door
Openings
Number of Unauthorized Service Door
Openings (0~255)
27 ItAd
Interval Authorized Service Door
Openings
Number of Unauthorized Service Door
Openings (0~255)
28 ItUC
Interval Unauthorized Coin Vault
Openings
Number of Authorized Service Door
Openings (0~255)
29 ItAC Interval Authorized Coin Vault Openings
Number of Authorized Service Door
Openings (0~ 255)
30 Ittl Interval Total Income
Amount of money for Total Income
(0,00~65535)
31 Actl Accumulated Total Income
Amount of money for Total Income
(0,00~65535)
32 IttC Interval Total Cycles Number of Total cycles (0~65535)
33 ACtC Accumulated Total Cycles Number of Total cycles (0~65535)
34 SCPr Super Cycle Price Scpr is not available in dryer. (It can’t enter.)
35 toPr Top O Price 0,00~9,90
36 Itd Interval Money
Amount of money for regular cycle
(0~65535)
37 ACd Accumulated Money
Amount of money for regular cycle
(0~65535)
38 Ittd Interval Topo Money Amount of money for Topo (0~65535)
39 ACtd Accumulated Topo Money Amount of money for Topo (0~65535)
INTERVAL means collecting since last data collection.
ACCUMULATED means collecting over a period of time since last factory reset (EEPt).
Authorized: Turning on/o the toggle switch with PDA Communication.
(Turning on/o the toggle switch within 30 minutes after Communicating with PDA)
Unauthorized: Turning on/o the toggle switch without PDA Communication.
MFL62512875_150414.indd 45 2015.4.14 9:44:8 AM