Single CAC Outdoor Unit
2. Specifications
10
Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit
AUUW18GAE
[UU18W UE4]
AUUW18GAE
[UU18W UE4]
Indoor unit
ATNW18GQLA0
[CT18 NQ4]
ABNW18GM1A0
[CM18 N14]
Capacity
Cooling
Min.~Rated~Max. kW 2.00 ~ 5.00 ~ 5.50 1.80 ~ 5.00 ~ 6.00
Min.~Rated~Max. Btu/h 6,800 ~ 17,100 ~ 18,700 6,100 ~ 17,100 ~ 20,500
Heating
Min.~Rated~Max. kW 2.20 ~ 5.80 ~ 6.80 2.20 ~ 6.00 ~ 7.20
Min.~Rated~Max. Btu/h 7,500 ~ 19,800 ~ 23,200 7,500 ~ 20,500 ~ 24,600
Power Input
Cooling Rated kW 1.56 1.46
Heating Rated kW 1.66 1.66
Running Current
Cooling Rated A 7.10 6.50
Heating Rated A 7.50 7.60
SEER / SCOP Wh / Wh 6.10 / 4.25 6.10 / 4.15
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 287 / 1,351 287 / 1,383
Combination
Outdoor unit
AUUW18GAE
[UU18W UE4]
Indoor unit
ABNH18GL2A2
[CB18 N22]
Capacity
Cooling
Min.~Rated~Max. kW 2.00 ~ 5.00 ~ 6.00
Min.~Rated~Max. Btu/h 6,800 ~ 17,100 ~ 20,500
Heating
Min.~Rated~Max. kW 2.20 ~ 6.00 ~ 7.20
Min.~Rated~Max. Btu/h 7,500 ~ 20,500 ~ 24,600
Power Input
Cooling Rated kW 1.55
Heating Rated kW 1.50
Running Current
Cooling Rated A 6.80
Heating Rated A 8.40
SEER / SCOP Wh / Wh 6.10 / 3.95
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - A++ / A
Annual Energy Consumption Cooling / Heating kWh 287 / 1,418
Combination
Outdoor unit
AUUW18GAE
[UU18W UE4]
AUUW18GAE
[UU18W UE4]
Indoor unit
UVNH18GJLA2
[CV18 NJ2]
AQNH18GALA0
[CQ18 NA0]
Capacity
Cooling
Min.~Rated~Max. kW 1.92 ~ 5.00 ~ 5.80 2.20 ~ 5.00 ~ 5.60
Min.~Rated~Max. Btu/h 6,500 ~ 17,100 ~ 19,800 7,500 ~ 17,100 ~ 19,100
Heating
Min.~Rated~Max. kW 2.00 ~ 5.20 ~ 6.00 2.20 ~ 4.80 ~ 5.80
Min.~Rated~Max. Btu/h 6,800 ~ 17,700 ~ 20,500 7,500 ~ 16,400 ~ 19,800
Power Input
Cooling Rated kW 1.46 1.55
Heating Rated kW 1.53 1.50
Running Current
Cooling Rated A 6.70 7.00
Heating Rated A 6.90 6.90
SEER / SCOP Wh / Wh 6.10 / 4.15 6.20 / 3.81
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - A++ / A+ A++ / A
Annual Energy Consumption Cooling / Heating kWh 287 / 1,349 282 / 1,396