-102/143-
LG Electronics Inc.
VX11000
Check flow
Check flow
START
Check the clock to Camera
at U6000 (36MHz)
Check the Control signal
CAM_DATA[0:7], CAM_RESET/,
CAM_SDA, CAM_SCL
Check CON7007 Soldering
Replace U6000
Replace the Camera module
Camera will work properly
Re-soldering CON6000
YES
NO
YES
NO
NO
NO
NO
YES
YES
YES
Check the clock from Camera
at R6013 : CAM_PCLK
Check the voltage of
the following camera power :
+2.8V_CAM_VDDA
+2.6V_CAM_VDDIO
+1.8V_CAM_VDD
+2.8V_CAM_LVDD
Replace the U4001, U4002
Check the CON6000