COMPLAINT
CAUSE
REMEDY
Fan
motor
will
not
run.
Fan
motor
runs
intermittently
Fan
motor
noise.
Compressor
will
not
run,
but
fan
motor
runs.
No
power
Check
voltage
at
outlet.
Correct
if
none.
Power
supply
cord
Rotary
switch
Check
voltage
to
rotary
switch.
If
none,
check
power
supply
cord.
Replace
cord
if
circuit
is
open.
Check
switch
continuity.
Refer
to
wiring
diagram
for
terminal
identification.
Replace
switch
if
defective.
Wire
disconnected
or
connection
loose
Connect
wire.
Refer
to
wiring
diagram
for
terminal
identification.
Repair
or
replace
loose
terminal.
Capacitor
(Discharge
capacitor
before
testing.)
Test
capacitor.
Replace
if
not
within
+10%
of
manufacturer's
rating.
Replace
if
shorted,
open,
or
damaged.
Will
not
rotate
Revolves
on
overload.
Fan
Fan
blade
hitting
shroud
or
blower
wheel
hitting
scroll.
Realign
assembly.
Units
using
slinger
ring
for
condenser
fan
must
have
1/4
to
5/16
inch
clearance
to
the
base.
If
it
hits
the
base,
shim
up
the
bottom
of
the
fan
motor
with
mounting
screw(s).
Check
fan
motor
bearings;
if
motor
shaft
will
not
rotate,
replace
the
motor.
Check
voltage.
If
not
within
limits,
call
an
electrician.
Test
capacitor.
Check
bearings.
Does
the
fan
blade
rotate
freely?
If
not,
replace
fan
motor.
Pay
attention
to
any
change
from
high
speed
to
low
speed.
If
the
speed
does
not
change,
replace
the
motor.
If
cracked,
out
of
balance,
or
partially
missing,
replace
it.
Blower
Loose
clamper
If
cracked,
out
of
balance,
or
partially
missing,
replace
it.
Tighten
it.
Worn
bearings
Voltage
If
knocking
sounds
сод
replace
the
mot