When
checking
the
voltage
between
connector
the
PWB
assy(Power)
during
washing.
is
the
voltage
AC
220-240V?
Replace
the
PWB
assy
(Power)
After
power
off,
is
the
resistance
of
wire
connector
10
to
302?
After
power
off
the
heater
terminal
is
disconnected,
is
the
resistance
10
to
30.2?
Replace
the
heater
assy
When
disconnect
the
connector
on
the
PWB
assy
(Main),
is
the
resistance
of
the
wire
connectors
(Blue/
White)
between
2.5k
2
to
180k
2(105C
~0T)?
Replace
the
thermistor
(6322FR2046B)
When
checking
thermistor
on
the
tub
cover,
is
the
thermistor
unfixed
above
2mm
from
the
rubber?
Push
the
thermistor
tightly
to
the
rubber.