* Used for alternative connection methods, described in detail in the C-DiGit
Blot Scanner User Guide on the Resource CD.
Unpack C-DiGit® Blot Scanner
Place the C-DiGit Blot Scanner away from heat sources (furnaces, windows,
etc.) and out of direct sunlight.
Place C-DiGit Blot Scanner in Lab
Install Image Studio
Software
Windows® 7, 8, 8.1, or 10:
Important: You must be logged in to Windows using an Administrator
account. If necessary, log out and back in using an Administrator account.
1. Place installation CD into drive.
2. If installation does not start immediately, browse to the CD and open
Win_Image Studio Digits_5.x.x.exe.
3. Click Next and follow the instructions in the Setup Wizard.
NOTE: If you are using Windows 10, a separate driver must be installed to
connect your C-DiGit Blot Scanner to Image Studio Software via USB.
Learn more at licor.com/c-digit-driver
Mac OS X 10.9, 10.10, 10.11, or 10.12:
1. Place installation CD into drive.
2. If installation does not start immediately,
browse the desktop and double-click on
MacImageStudioDigits_5.x.x.dmg
3. Click Agree to accept the license agreement.
4. To install, drag the Image Studio icon onto
the Applications icon (right).
LAN
USB
Amphenol
12VDC 1A
Remove the yellow warning label on the C-DiGit Blot Scanner back panel.
Remove Warning Label
N. America, Japan
United Kingdom
Australia
Europe
P
U
S
H
LOCK
OPEN
Turn clockwise
to lock
Push button and
turn counterclockwise
to release
The power supply has interchangeable AC plugs for use in North America and
Japan, Australia, Europe, and the United Kingdom. Install the appropriate plug
on the power supply as shown.
Install Power Supply Plug
The power supply has the
North America/Japan plug
pre-installed.
P
U
S
H
LOCK
OPEN
AC Power
C-DiGit Blot Scanner
Computer
USB Connection
C-DiGit
USB Connection
C-DiGit
Power Connection
BSU
12VDC 1A
Connect the larger of the two connectors on the USB cable to your computer,
and the smaller end to the C-DiGit Blot Scanner back panel at the connector la-
beled ‘USB’. Connect the power supply plug to the jack on the rear panel la-
beled ‘12VDC 1A’.
Connect USB Cable and Power
Power the C-DiGit Blot Scanner on with the power switch on the back panel.
The blue power light on the instrument front panel (below) illuminates when
the instrument is powered on.
Turn on C-DiGit Blot Scanner
When the C-DiGit Scanner is powered on and connected
to the computer for the first time, drivers are automati-
cally installed on the computer. Allow up to 5 minutes
for the drivers to install before starting the Image
Studio Software in Step 9 below. NOTE: You may have
to dismiss any ‘Found New Hardware’ messages.
Wait While USB Drivers Install
Double-click the Image Studio icon on the desktop to start
the Image Studio Software.
Start Image Studio Software
PC: Click Create New. Navigate to where the folder will reside and name
the folder. Click Save.
Create New Work Area Folder
The Work Area is simply a folder on the hard drive or network where
all of the images, analyses, and settings are stored.
Mac: Click OK to use the default work area, or click Create New. Name the
folder and navigate to where the folder will reside. Click Save.
Power Supply
and Plugs
Ethernet
Cable*
USB
Cable
C-DiGit
Target
Image Studio
and Resource
CDs

Other manuals for LI-COR C-DiGit

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LI-COR C-DiGit and is the answer not in the manual?

LI-COR C-DiGit Specifications

General IconGeneral
ModelC-DiGit
Dynamic range>4 orders of magnitude
Scan area25 x 25 cm
Dimensions43 x 56 x 18 cm (17 x 22 x 7 inches)
Weight11.4 kg (25 lb)
ApplicationWestern blot documentation
Detection MethodFluorescence
Resolution21 μm
Power Requirements100–240 VAC, 50/60 Hz
Image FormatTIFF
ConnectivityUSB
Laser Wavelengths680 nm and 780 nm