CL-2 Service Manual
6. Error Code
Error Code Explanation
ERR_CODE_UV Rejected by UV
ERR_CODE_MG Rejected by MG
ERR_CODE_IR Rejected by IR
ERR_CODE_RECO Failed to recognize denomination
ERR_CODE_ROI Failed to recognize edge of notes
ERR_CODE_SC Short size is different from Count mode
ERR_CODE_LC Width size is different from Count mode
ERR_CODE_DENOM Different denomination from SP mode
ERR_CODE_SN Failed to recognize Serial Number
ERR_CODE_FACE Rejected by Front / Back recognition.
ERR_CODE_ORIENT Rejected by Up / Down recognition.
ERR_CODE_ISSUE Rejected by Issued Version
ERR_CODE_BATCHFULL When the notes reached Batch size
ERR_CODE_STACKERFULL When the notes reached Stacker size
ERR_STACKER Stacker Remain, please clean the stacker before the count.
ERR_BACTCH_ALARM When the notes are removed from Stacker even though counted notes are not reached batch size.
ERR_CODE_TIMEOUT1 Failed to get ROI information
ERR_CODE_TIMEOUT2 Failed to get recognition information
ERR_CODE_TIMEOUT3 Failed to get CF recognition information
68