Lifebreath 200STD User Manual

Lifebreath 200STD
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
OTHER
INSTALLATION
METHODS
DIRECT
CONNECTION
of
the
SUPPLY
AIR
STREAM
to
the
FURNACE
COLD
AIR
RETURN
of
LIFEBREATH
HRVs
Balancing
damper*
in
*Unit
is
normally
balanced
on
HIGH
i
both
air
streams.
*Unit
is
normally
balanced
on
HIGH
speed
with
furnace
blower
OFF.
<=^Z
Outdoors
Forced
Air
Furnace
Combustion
or
Electric
Cold
Air
Return
m.
exm*
ie.ba
£=C>
m
m
E=i>
R
EXHAUST
AIR
from
various
parts
of
home.
®
i.e.
bathrooms
(if
required),
kitchens
(if
required),
rooms
without
operable
windows,
etc.
and
potentially
basements.
NOTES:
1.
Furnace
blower
need
not
operate
to
provide
good
air
distribution/quality
with
this
system.
2.
Should
furnace
blower
be
required
to
operate
to
help
distribute
supply
air,
it
may
be:
A)
-
interlinked
electrically
(low
voltage)
with
HRV
for
intermittent
demand
or,
B)
-
run
continuously,
though
electrical
consumption
of
furnace
blower
should
be
considered.
3.
No
separation
requirements
necessary
between
direct
connection
point
and
furnace.
4.
Air
streams
through
HRV
do
not
represent
any
particular
model.
They
may
change
in
actual
installation.
5.
Weatherhood
arrangement
is
for
drawing
purposes
only.
Six
ft.
(6')
minimum
separation
required.
Ten
in.
(10")
above
grade
minimum.
FIG.
6
DIRECT
CONNECTION
of
both
the
LIFEBREATH
HRV
SUPPLY
AIR
STREAM
and
EXHAUST
AIR
STREAM
to
the
FURNACE
COLD
AIR
RETURN
Forced
Air
Furnace
Combustion
or
Electric
Balancing
damper*
in
both
air
streams.
*Unit
is
normally
balanced
on
HIGH
speed
with
furnace
blower
operating.
Outdoors
NOTES:
1.
Furnace
blower
is
required
to
operate
when
ventilation
from
HRV
is
required
(when
HRV
is
running).
It
may
be:
A)
-
interlinked
electrically
(low.voltage)
with
HRV
for
intermittent
demand
or,
B)
-
run
continuously,
though
electrical
consumption
of
furnace
blower
should
be
considered.
2.
A
minimum
separation
of
18"
is
required
between
the
two
direct
connections.
3.
The
exhaust
air
connection
should
be
upstream
of
the
supply
air
connection
to
prevent
exhausting
any
fresh
air.
4.
Air
streams
through
HRV
do
not
represent
any
particular
model.
They
may
change
in
actual
installation.
5.
Weatherhood
arrangement
is
for
drawing
purposes
only.
Six
ft.
(6)
minimum
separation
required.
Ten
in.
(10")
above
grade
minimum.
FIG.
7
9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lifebreath 200STD and is the answer not in the manual?

Lifebreath 200STD Specifications

General IconGeneral
BrandLifebreath
Model200STD
CategoryFan
LanguageEnglish