1105
6 3/4" Aperture Step Baffle Reflector Trim
Page 4 of 4
Philips Lightolier
e: lol.webmaster@philips.com
t: (508) 679-8131
w: www.lightolier.com
1105 November 14, 2011
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2011. All rights reserved.
Job Information Type:
100
200
60°
30°
300
0
Zonal lumens and percentages
Zone Lumens %Lamp %Luminaire
0-30 269 15.65 43.00
0-40 428 24.89 68.38
0-60 611 35.57 97.73
0-90 626 36.40 100
**Efficiency =36.4%
Angle Mean CP
0 298
5 308
10 326
15 335
20 330
25 318
30 293
35 256
40 207
45 156
50 109
55 67
60 32
65 10
70 2
75 0
80 0
85 0
90 0
Tested according to IES Procedures.
Test distance exceeds five times the
greatest luminous opening of luminaire.
1500
60°
30°
4500
3000
0
Tested according to IES Procedures. Test
distance exceeds five times the
greatest luminous opening
of luminaire.
Coefficients of utilization
Ceiling 80% 70% 50% 0%
Wall 50 30 10 50 30 10 50 30 10 0
% WALL RELECTANCE
Room Cavity Ratio
1 .40 .39 .38 .39 .38 .38 .38 .37 .36 .34
2 .37 .35 .34 .36 .35 .34 .35 .34 .33 .31
3 .34 .32 .30 .33 .32 .30 .32 .31 .30 .28
4 .31 .29 .27 .31 .29 .27 .30 .28. .27 .28
5 .29 .26 .24 .28 .26 .24 .28 .26 .24 .23
6 .26 .24 .22 .26 .24 .22 .25 .23 .22 .21
7 .24 .21 .20 .24 .21 .20 .23 .21 .20 .19
8 .22 .20 .18 .22 .19 .18 .21 .19 .18 .17
9 .20 .18 .16 .20 .18 .16 .20 .17 .16 .15
10 .18 .16 .14 .18 .16 .14 .18 .16 .14 .14
20% Floor Cavity Reflectance
Conversion Factors: 2 Lt. 13W Quad Tube: White, C.U. x 1.25. 1
Lt 13W Quad Tube: Black, C.U. x 1.3; White, C.U. x 1.5. 150W A21:
Black, C.U. x 1.25; White, C.U. x 1.7. 100W A19: Black,
C.U. x 1.25; White C.U. x 1.7.
The coefficients of utilization remain the same.
Coefficients of utilization
Ceiling 80% 70% 50% 0%
Wall 50 30 10 50 30 10 50 30 10 0
% WALL RELECTANCE
Room Cavity Ratio
1 .98 .96 .95 .96 .95 .93 .93 .92 .91 .84
2 .94 .92 .89 .92 .90 .89 .90 .88 .87 .82
3 .90 .88 .85 .89 .87 .85 .87 .85 .84 .80
4 .87 .84 .82 .87 .84 .82 .85 .83 .81 .78
5 .85 .81 .79 .84 .81 .79 .82 .80 .78 .76
6 .82 .79 .77 .82 .79 .76 .80 .78 .76 .74
7 .80 .76 .74 .79 .76 .74 .78 .75 .74 .72
8 .77 .74 .72. .77 .74 .72 .76 .73 .71 .70
9 .75 .72 .70 .75 .72 .70 .74 .71 .69 .68
10 .73 .70 .68 .73 .70 .68 .72 .69 .68 ..66
20% Floor Cavity Reflectance
Conversion Factors: 150W PAR38 FL: White, C.U. x 1.1. 150W
BR40FL: Black, C.U. x 0.95; White C.U. x 1.1.
Certified Test Report No. 2183
Computed by LSI Program **TEST-LITE** Recessed Lytecaster Downlight 6 1/2" Dia. Aperture,
Matte Black Step Baffle Two 13W DTT Lamps, Lumen Rating = 860 LMS.
Certified Test Report No. 2108
Computed by LSI Program **TEST-LITE** Recessed Lytecaster Downlight 6 1/4" Dia. Aperture,
Matte Black, Black Step Baffle One 150W PAR38 Flood Lamp. Lumen Rating = 1740 LMS.
Zonal lumens and percentages
Zone Lumens %Lamp %Luminaire
0-30 1335 77 89.13
0-40 1470 84.48 98.13
0-60 1498 86.10 100
0-90 1498 86.10 100
**Efficiency =86.1%
Angle Mean CP
0 5295
5 4790
10 3537
15 2043
20 1014
25 544
30 351
35 207
40 94
45 22
50 3
55 0
60 0
65 0
70 0
75 0
80 0
85 0
90 0