User's guide
SMAX
• Cost-effective absolute linear encoder
• Measuring length up to 600 mm / 23.622”
• Resolution down to 0.1 mm
• SSI and voltage/current analogue interfaces
• Up to IP69K protection rate
Suitable for the following models:
• SMAX-BG-...
• SMAX-GG-...
• SMAX-AI1-...
• SMAX-AV2-...
Table of Contents
1 - Safety summary 7
2 - Identification 8
3 - Mounting instructions 9
4 - SSI interface 13
5 - Analogue interface 20
6 - Diagnostic LED 28
7 - Maintenance 29
8 - Troubleshooting 30
Lika Electronic • Tel. +39 0445 806600 • info@lika.biz • www.lika.biz
Smart encoders & actuators

Questions and Answers

  • T
    Trevor ThomasAug 1, 2025
    Why are the measured values inaccurate with my Lika SMAX-BG Accessories?
    • C
      Chad FinleyAug 1, 2025
      Inaccurate measured values with Lika Accessories can occur for several reasons. It could be that the gap between the sensor and the scale isn't consistent along the entire measuring length, or the sensor isn't properly installed on the scale. Another cause might be the connection cable running near high voltage cables or a poorly connected shield, so check the earthing point. Also, the frequency of the Master clock might be set too high or too low, disrupting synchronization, so check the “4 - SSI interface.” Furthermore, a section of the magnetic scale might be mechanically or magnetically damaged. Finally, the measuring error could be due to torsion in the machine structure; in this case, check parallelism and symmetry in the machine's movement.
  • M
    mchangAug 16, 2025
    What to do if Lika SMAX-BG Accessories system does not work (no pulse output)?
    • H
      Heather BarajasAug 16, 2025
      If your Lika Accessories system isn't working and there's no pulse output, first, check if the scale and/or the sensor are installed properly, ensuring the active surface of the scale matches the sensor's sensitive part and that the sensor is correctly oriented. For correct installation please refer to the “3 Mounting instructions” section on page 9. Also, make sure there are only non-magnetic materials between the sensor and the scale. Verify that the installation complies with the tolerance gap between the sensor and the scale, and check the sensor's sensitive part for damage. The issue also can be caused by the sensor being damaged by short circuit or wrong connection.

Summary

Typographic and Iconographic Conventions

Conventions Explained

Explains the use of colors and icons for better understanding of the manual content.

Preliminary Information

Document Overview and Scope

Provides an overview of the SMAX encoder and the manual's structure.

1 - Safety Summary

General and Electrical Safety

Covers essential safety guidelines for installation, operation, and electrical connections.

Mechanical Safety

Outlines safety measures related to mechanical handling and installation.

2 - Product Identification

Identification Methods

Explains how to identify the device using order codes and serial numbers.

3 - Mounting Instructions

Dimensions and Magnetic Tape

Provides physical dimensions and information on the magnetic tape.

Sensor Mounting Procedure

Step-by-step guide for physically installing the sensor.

Measuring Length and Counting Direction

Details the maximum measuring length and the standard counting direction.

4 - SSI Interface

SSI Electrical Connections and Specifications

Details wiring, M8 cable specs, and M12 connector pinout for the SSI interface.

Shield, Grounding, and Input Functions

Explains shield/ground connections, zero setting, and counting direction inputs.

SSI Protocol and Transmission

Introduces SSI technology, MSB protocol, and recommended transmission rates.

Recommended SSI Circuit

Shows a typical circuit diagram for the SSI interface connection.

5 - Analogue Interface

Analogue Electrical Connections and Specifications

Details wiring, M8 cable specs, and M12 connector for analogue outputs.

Analogue Signals and Fault Output

Explains analogue signals (START, STOP, outputs) and fault output functionality.

TEACH-IN Procedure and Ramps

Guides on setting analogue output range using TEACH-IN and defining ramps.

Analogue Output Circuits

Provides recommended circuit diagrams for current and voltage analogue outputs.

6 - Diagnostic LED

LED Status Indicators

Explains the meaning of different LED states for diagnostics.

7 - Maintenance

Maintenance Procedures

Outlines recommended maintenance operations for the system.

8 - Troubleshooting

Common Faults and Solutions

Lists typical faults and their possible causes and solutions.

Lika SMAX-BG series Specifications

General IconGeneral
BrandLika
ModelSMAX-BG series
CategoryAccessories
LanguageEnglish