Light does
not work.
Wires are not properly connected.
Light bulb is faulty.
Ensure wire connector in the switch housing
is connected.
Remove light bulb and replace with a new
one of the same type.
Fan does
not seem to
provide the
expected
effects.
Fan is in reverse mode (blades are
moving in a clockwise direction).
Fan is not properly connected.
Counter-clockwise (forward) direction is
recommended in warm weather. Switch off
fan and power, and wait for rotation to stop.
Use the eraser end of a pencil to push the
forward/reverse switch up.
Adjust the fan so that the ends of t
he blades
have at least 12” (30 cm) clearance from
walls or other obstructions, in the centre of
the room.
Fan
wobbles
or shakes
excessively.
Screws securing blades to motor are
loose.
Screws securing blade assembly are
loose.
Mounting bracket is not tightened
securely.
Tighten the screws.
Tighten the screws.
Tighten the mounting bracket to the outlet
box.
If the ceiling fan works abnormally, follow the instructions below or consult a qualified electrician.
WARNING!
To avoid possible electric shock, switch off the power supply at the main fuse or
circuit breaker box before servicing.
Problem Possible Reason
Solution
Fan is noisy
during
operation.
Fan does
not start.
Blade screws are loose.
The mounting bracket or canopy is
loose.
Screws securing decorative housing to
mounting bracket are loose.
Glass shade is loose.
Screws securing down rod to mounting
bracket are loose.
Wiring connectors are vibr
ating against
the inside of the canopy.
Light kit or light bulb is not firmly
attached.
Canopy is rattling against ceiling.
Motor housing screws are loose.
Tighten the blade screws.
Check and fasten the screws.
Check and fasten the screws.
Tighten by hand, as necessary.
Check and fasten the screws.
Disconnect power at fuse box, loosen
canopy and reposition connectors.
Remove and reattach.
Be sure canopy is not touching ceiling.
Check and fasten the screws.
Fuse or circuit breaker is blown.
Loose or incorrect power line
connections to the fan or switch wires.
Re
verse switch is stuck in the middle.
Check main fuse and branch circuit fuses or
circuit breaker. Repair as necessary.
Check all the wiring connections to fan and
housing wiring. Repair as necessary.
Make sure the reverse switch is set to up or
down only.
13