Lincoln Quicklub 203 Series Specifications

General IconGeneral
BrandLincoln
ModelQuicklub 203 Series
CategoryLubrication systems
LanguageEnglish

Summary

Safety Instructions

Installation

Identification Code - Pump Models 203

Basic Pump Model and Reservoir Design

Explains the initial part of the code for basic model, reservoir type, and low-level control.

Pump Element and Supply Voltage Codes

Details codes for pump element type/diameter and supply voltage (12VDC, 24VDC, AC).

Connection Possibilities and Types

Describes codes for electrical connections (number of possibilities, plug types) and external connections.

Control PCB and Special Codes

Explains codes for control printed circuit boards (V10-V13, M08-M23, H) and ADR variants.

Mode of Operation

Pump Elements with Fixed Lubricant Output

Explains the operation of pump elements with fixed output, including suction and dispensing phases.

Pump Element with Adjustable Lubricant Output

Describes the operation of adjustable pump elements and their output ranges.

Setting of Adjustable Pump Elements

Step-by-step instructions on how to adjust the output of pump elements using the adjusting spindle.

Retrofit Adjustment of Max. Lubricant Output

Procedure for accurately setting the maximum lubricant output of adjustable pump elements.

Adjusting of Small Lubricant Outputs

Instructions for fine-tuning the pump element for small lubricant output settings.

Maintenance, Repair and Tests

Replace pump element

Step-by-step guide for removing and installing a pump element, including torque specifications.

To Check the Pressure Relief Valve

Methods to test the pressure relief valve's opening pressure using a gauge or manual pump.

Troubleshooting

Fault: The pump motor does not run

Lists causes like power interruption or motor defect and remedies like checking fuses and supply.

Fault: The pump does not deliver the lubricant

Identifies causes like an empty reservoir or air bubbles and suggests remedies like refilling or bleeding.

Technical Data

Pump, Motor, and Element Specifications

Covers pump/motor details, lubricant output for pump elements, valve specs, torques, and weights.

Connection Diagrams

Illustrates wiring for pumps without control units using square-type, bayonet, and M12 connectors.