Do you have a question about the Line Seiki E60 Series and is the answer not in the manual?
Displays the current count value on the front panel.
Shows preset values and programming settings on the front panel.
Indicates the status of the output signal on the front panel.
Shows the status of the external reset input on the front panel.
Indicates if the key lock function is active on the front panel.
Keys for setting individual digits of preset or program values.
Button used to reset the counter or its values.
Key used for mode switching and program item selection.
Shows the current program item being displayed or set.
Setting preset values and normal counting are done in Run Mode.
Used for initial settings like count speed, output mode, and prescale.
Selectable count speeds from 30Hz to 10kHz.
Choose between contact, open collector, or voltage input.
Select add/subtract or 90° quadrature input.
Details available output modes like Standard, Equal, Limits.
Configure output time for one-shot or hold modes.
Set prescale ratio for displaying desired units.
Set the position of the decimal point for display.
Set initial count value for reset operations.
Set minimum pulse time for remote reset signals.
Configure key lock levels for operational restrictions.
Configures input signal type (contact/voltage).
Sets count speed (Low/High).
Selects count mode (add/subtract or quadrature).
Sets output time (Hold or One-Shot).
Configures operation mode (e.g., Auto Reset).
Enables/disables input signals (DP4 & DP5).
Sets reset time (2ms or 20ms).
Enables or disables key lock functionality.
Unit counts while output signal is active.
Unit does not count during active output signal.
Unit does not count during or after output signal.
Resets the unit at the rising edge of the output signal.
Resets at falling edge of output (one-shot time only).
Auto-reset at falling edge, display frozen during output.
Auto-reset at falling edge, does not count during output.
Setting count speed via program mode using keys.
Selecting output modes like Standard, Equal, Limits.
Setting output time for OUT1 and OUT2.
Choosing operation modes A through G.
Setting the prescale value for display scaling.
Setting the decimal point position via program mode.
Setting the initial value for write/reset.
Setting the minimum reset pulse time.
Selecting the key lock protection level.
Diagrams showing terminal connections for E60-101, E60-201, E60-301 models.
Instructions for connecting the AC 100-240V power supply.
Details for connecting contact, open collector, voltage, and quadrature inputs.
Wiring for relay outputs (N.O., N.C., COM) and open collector output.
How to connect terminals for remote reset.
Connection for activating count inhibit (standard models).
Connection for activating key lock (K-type models).
Operation example for Mode A with Standard Output in 2-level preset.
Operation example for Mode A with Equal Output in 2-level preset.
Operation example for Mode A with Limit Outputs in 2-level preset.
Operation example for Mode B with Standard Output in 2-level preset.
Operation example for Mode C with Standard Output in 2-level preset.
Operation example for Mode D with Standard Output in 2-level preset.
Operation example for Mode E with Standard Output in 2-level preset.
Operation example for Mode F with Standard Output in 2-level preset.
Operation example for Mode G with Standard Output in 2-level preset.
Operation example for Mode A with Standard Output (1-level+prewarn).
Operation example for Mode A with Equal Output (1-level+prewarn).
Operation example for Mode B with Standard Output (1-level+prewarn).
Operation example for Mode C with Standard Output (1-level+prewarn).
Information on model numbers and display characteristics.
Number of digits and preset levels supported.
Configurable setting range and prewarn functionality.
Details on supported input modes and signal types.
Specifications for count speed and counting modes.
Parameters for count range and prescale settings.
Configuration for decimal point position and write values.
Information on reset functions and remote reset timing.
Supported operation modes and memory characteristics.
Details on count inhibit and key lock features.
Specifications for output types and delay times.
Available output modes and their timing configurations.
Information on error indications and power supply requirements.
Specifications for sensor power source and power consumption.
Environmental operating conditions and protection ratings.
Details on compliance standards and product weight.
Physical dimensions and panel cutout size.
| Brand | Line Seiki |
|---|---|
| Model | E60 Series |
| Category | Cash Counter |
| Language | English |