EasyManua.ls Logo

Linear Access AK-11 - AK-11 Master Reset and Code Reset; Master Reset Procedure; Resetting the Master Code

Linear Access AK-11
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 4 0
#
Sound
#
Sound = 1 for Yes = 0 for No
Beep Sounds During Relay #1 Default: No
Selects whether or not the keypad beeps during Relay #1 activation.
Press: 4 1
#
Sound
#
Sound = 1 for Yes = 0 for No
Beep Sounds During Relay #2 Default: No
Selects whether or not the keypad beeps during Relay #2 activation.
Press: 4 2
#
Sound
#
Sound = 1 for Yes = 0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3 activation.
Press: 4 3
#
Sound
#
Sound = 1 for Yes
= 0 for No
Beep Sounds During Output #4 Default: No
Selects whether or not the keypad beeps during Output #4 activation.
Press: 4 4
#
Sound
#
Sound = 1 for Yes
= 0 for No
Keypad Lockout Count Default: 3 Tries
Sets the number of incorrect entry code attempts allowed before the
keypad “locks out”.
Press: 5 0
#
Attempts
#
Attempts = Number of attempts before lockout (2-7)
Anti-passback Time Default: No Anti-passback
Sets the length of time an entry code will not function after it is used.
Press: 5 1
#
Minutes
#
Minutes = Time in Minutes (1-4)
0 = No Anti-passback
Master Reset
! CAUTION: Performing a master reset will clear the entire
memory of the AK-11 and return all programmable options
to the factory default values. ALL ENTRY CODES WILL BE
ERASED.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the
*
and
#
keys.
STEP 3 Apply power to the keypad, continue holding the keys down
until the red LED starts flashing.
STEP 4 Release the keys. The red and yellow LEDs will remain lit
until the process is complete, then the yellow LED will go out.
Resetting the Master Code
STEP 1 Open the AK-11 case.
STEP 2 Locate jumper JP2. This jumper is used to reset the master
code.
STEP 3 With power applied to the keypad, remove jumper JP2. The
keypad will begin to beep, signaling that the code has been
reset.
STEP 4 Replace jumper JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.