APPARECCHIO DI EMERGENZA
EMERGENCY LUMINAIRE
CRISTAL
REST MODE
IP40-IP65
ISTRUZIONI PER L'INSTALLAZIONE E L'USO
INSTALLATION AND USE INSTRUCTIONS
I
UK
Attenzione: In caso di installazione a parete il prodotto deve essere
disposto con i led verso il BASSO
BATTERIE:
Sostituire la batteria ogni quattro anni o quando l'autonomia non è
più quella nominale. C'è uno spazio da riempire a cura
dell'installatore con la data di entrata in funzione.
Attenzione: Le batterie al Ni-Cd e Ni-MH sono inizialmente
scariche, la prima ricarica deve durare almeno 48h.
Warning: In case of wall mounting the product must be positioned
with the leds down.
BATTERIES:
It is recommended to substitute each battery every four years or when
the nominal autonomy is not guaranteed. The model and the date of
production of the battery are written on it. Fill the field with the date of
the first starting (Fig.1).
Warning: The Ni-Cd and Ni-MH batteries are sold uncharged: the
first charge must be 48h long.
GENERAL CHARACTERISTICS:
- Indicator green Led for the presence of the power supply.
- Operation with rechargeable Ni-Cd and NiMH batteries.
- Constant current electronic device for the charge of the battery.
- Electrical protection device for the excessive discharge of battery.
- Possibility to be put in the stand-by mode by remote control
Commander (optional)
- Possibility to put a green signal label .
- Plastic body in accordance with the rules in force.
CARATTERISTICHE GENERALI:
- Led spia verde per presenza rete.
- Funzionamento con batterie ricaricabili al Ni-Cd e al NiMH.
- Dispositivo di ricarica delle batterie a corrente costante.
- Dispositivo di protezione contro la scarica eccessiva della batteria.
- Possibilità di messa in stato di riposo tramite il comando remoto
Commander (opzionale).
- Possibilità di applicare dei pittogrammi di segnalazione.
- Corpo in materiale plastico conforme alle normative vigenti.
EN 60598-1 EN 60598-2-22
2002/95/CE RoHS Compliant
MADE IN ITALY
230 Vac - 50 Hz
INSTALLAZIONE: (FIG.2)
-Rimuovere il diffusore trasparente 1 facendo leva con
dei cacciaviti nei punti 2.
-Sganciare il riflettore 3 dalla base 4 facendo leva con un cacciavite
nel punto 5.
-Forare se necessario uno dei tre possibili ingressi laterali per il cavo
di alimentazione ed applicare
la base 4 al muro tramite gli appositi fori per il fissaggio.
-Eseguire i cablaggi come esposto in fig.3,4,5,6
-Riagganciare il riflettore 3 alla base 4 facendo scattare il denti nel
punto 5.
-Riagganciare il diffusore trasparente 1 alla base 4 facendo scattare i
denti nei punti 2.
INSTALLATION: (FIG.2)
-Remove the transparent cover 1 pushing with a screwdriver
in the points 2.
-Unhook the body of the lamp 3 from the base 4 with a screwdriver in
the point 5.
-Drill in necessary one of the three possible entries for the power
supply cable and fix the base 4 to the wall using the holes on the
base.
-Make the connections as shown on fig.3,4,5,6.
-Hook the body 3 to the base 4 making release the tooth on point 5.
-Hook the transparent cover 1 to the base 4 making release the tooth
on points 2.
N.B.
inserire i tappi in dotazione negli appositi spazi laddove
viene inserito il tassello per l’installazione, al fine di per
garantire la tenuta stagna dell’apparecchio.
INSERIRE IL RACCORDO
IN DOTAZIONE PER GARANTIRE
LA TENUTA STAGNA.
INSERT THE IP65 CONNECTOR
SUPPLIED TO ENSURE THE WATER-
TIGHT INTEGRITY OF THE FITTING.
5
5
4
3
2
2
2
2
1
Fig.2
Fig.2b
N.B.
In order to ensure the watertight integrity
of the fitting insert the covers coming with the product
in the reserved places where the screws anchors are
inserted.
ALIMENTAZIONE/ POWER SUPPLY
POTENZA ASSORBITA/ POWER ABSORPTION
GRADO DI PROTEZIONE/ PROTECTION DEGREE
CLASSE DI ISOLAMENTO/ INSULATING CLASS
SEZIONE DEL CAVO/ WIRE DIAMETER
CARATTERISTICHE TECNICHE/TECHNICAL CHARACTERISTICS
230Vac - 50Hz
6VA
IP 40-IP65
II
0,5 ÷ 5mm
2
03
Question and Answer IconNeed help?

Do you have a question about the Linergy CRISTAL Series and is the answer not in the manual?

Overview

The device described in this manual is the CRISTAL REST MODE emergency lighting fixture, designed for surface mounting. It is an apparatus for emergency lighting with a maintained or non-maintained operation mode, manufactured in Italy.

Function Description

The CRISTAL REST MODE fixture provides emergency lighting, automatically activating in the event of a power failure. It is designed to be easily installed and maintained. The device can be configured for either permanent (maintained) or non-permanent (non-maintained) operation, allowing it to function as a normal luminaire that also provides emergency light, or solely as an emergency light that activates only during power outages. The "REST MODE" functionality, indicated by the presence of a jumper J7, suggests a specific operational mode that might involve reduced power consumption or a particular standby state, which can be configured using a "Commander" device. This Commander device allows for remote inhibition of connected luminaires, providing a centralized control option for the emergency lighting system.

Important Technical Specifications

The CRISTAL REST MODE is suitable for operation with a voltage of 230 Vac at 50 Hz. It boasts an IP40 degree of protection, indicating resistance against solid objects larger than 1mm, and an IK05 degree of protection, signifying resistance to mechanical impact. The device is CE certified and RoHS compliant, ensuring it meets European safety, health, and environmental protection standards.

Key electrical characteristics and performance data vary depending on the specific model (e.g., CR08N10EGR, CR11N10EGR, CR18N10EGR, CR24N10EGR, CR08N30EGR, CR11N30EGR, CR18N30EGR, CR24N30EGR, and their IP65 counterparts). These models differ in lamp power (e.g., 8W, 11W, 18W, 24W), autonomy (1h or 3h), and battery type (NiCd 6V 1.0Ah, NiCd 6V 1.3Ah, NiCd 6V 2.5Ah, NiCd 6V 4.0Ah, NiMH 6V 1.0Ah, NiMH 6V 1.3Ah, NiMH 6V 2.5Ah, NiMH 6V 4.0Ah). The luminous flux (lm) also varies, ranging from approximately 170 lm to 507 lm, depending on the model and autonomy. The battery life for all models is specified as 12h. The maximum cable diameter for wiring is 0.5 - 2.5mm².

Usage Features

The device is designed for surface mounting. Its installation involves several steps:

  1. Preparation: Remove the transparent cover by unscrewing it with a screwdriver.
  2. Mounting: Unhook the body of the lamp from the base by removing the 3 screws from the back. Drill in the necessary one of the three possible entries for the power supply cable and fix the base to the wall using the holes on the base.
  3. Wiring: Make the electrical connections as shown in the wiring diagrams (Fig. 3, 4, 5). The manual provides specific diagrams for non-permanent (non-maintained) and permanent (maintained) installations, both with and without the "Commander" configuration. For non-permanent installations, the main supply is connected to terminals L and N, and an external test button can be connected. For permanent installations, the main supply is connected to L1 and N1, with L also connected to L1. The A-B terminals are crucial for the inhibition switch, which, when closed with a short wire, enables the emergency function.
  4. Final Assembly: Hook the body of the lamp to the base and fix it with the 3 screws. Hook the transparent cover to the base, making sure to align the tooth on point 5 with the tooth on point 2.

The device features an A-B inhibition switch. Closing this switch with a short wire enables the emergency function. Conversely, opening it disables the emergency function. This is a critical safety and control feature. The "Commander" device, when used, allows for remote inhibition of connected luminaires, providing a centralized control option.

Maintenance Features

Battery Maintenance: The manual strongly recommends replacing the battery every four years or when its autonomy falls below the specified duration. The date of production of the battery is written on it. The field with the date of the first charge must be filled. It is crucial to note that NiCd and NiMH batteries are sold charged, but the first charge must be at least 48 hours. This initial charge is essential for the battery to reach its full capacity and ensure proper operation.

General Maintenance: The device is designed for easy maintenance. The transparent cover can be easily removed for access to internal components, including the battery. The modular design, where the body of the lamp can be unhooked from the base, facilitates installation and subsequent maintenance tasks.

Troubleshooting: The manual advises against attempting to repair the electronic board in case of malfunction. Instead, it recommends replacing the entire electronic board. Any repairs or replacements should be carried out by authorized personnel to maintain the warranty.

Warranty Conditions: The warranty is valid for a period of 24 months from the date of sale. The warranty becomes void if the product is dismantled, modified, or repaired by unauthorized personnel.

Environmental Considerations: The manual includes information regarding the proper disposal of the device at the end of its life cycle, emphasizing that it should not be disposed of with general waste but rather taken to an authorized collection center for electrical and electronic equipment. This aligns with the RoHS compliance, promoting environmentally responsible practices.

In summary, the CRISTAL REST MODE is a versatile and robust emergency lighting fixture, offering various configurations and reliable performance, with an emphasis on ease of installation, user control, and straightforward maintenance.

Linergy CRISTAL Series Specifications

General IconGeneral
BrandLinergy
ModelCRISTAL Series
CategoryLighting Equipment
LanguageEnglish

Related product manuals