When unit is working as GSM modem then is busy for voice connection. When you pick up the line you will hear busy
tone.
The unit is monitoring data transmission by modem. The data transmission can not be permanent therefore the unit
stays in data mode 10 seconds after finishing of data transmission.
Then is going back to Voice mode (calling)
The same is when you are calling over unit. It is busy for data transmission.
The optional sw supply to unit for sending and receiving SMS messages is SMS mail. It is working under Outlook,
Outlook Express, Opera etc. And you can work with SMS as with normal e mails. ( see manual for SMS mail). It works in
batches and allows programs communication interval (1 to 99 minutes) to Link Gate A Premium for sending and
receiving SMS. Due this we avoid situation that unit is permanently blocked by data mode for voice communication.
Further functionality of USB is monitoring Link Gate A Premium operation. It is possible a record even incoming call
includes time and CLIP, signal strength, etc
CONFIGURATION
The programming mode is set after acknowledgement dialling to Link Gate A Premium. In the analogue phone is waiting
tone. After password inserting is tone changing to programming tone.
Then you can programming each features of Link Gate A Premium (via table of programming)
Progress of programming:
Dial 2 digits number of programming feature.
Dial 1 to 4 digits number for feature value programming.
Wait for a tone of confirming request (3 shorts tones).
Confirm the feature by dialling acknowledgement (#)
Wait for confirming tone.
Follow programming tone again.
Finish programming by hang up a phone.
Example: programming of new permitted fix numbers (02)
to memory 09:
Dial acknowledgement (default is #). In phone you are hearing waiting tone ( ). Dial password
(default 0000).
Waiting tone is changing to programming tone ( ).
Dial 1902. Wait for tone of confirming request (3 shorts tones).
Confirm the feature by dialling acknowledgement (#). Wait for confirming tone (one long tone). Finish programming
mode by hang up a phone.
Warning: After dialling of parameter value you have to wait for 3 short tones and then dial acknowledgement (#). Wait for
long tone confirms acceptation of this parameter.
Notes to each parameters:
11 19 When you program some prefixes the Link Gate A Premium allows outgoing calls starts by those prefixes only.
The others will get busy tone. When memories will be empty the calling wont be restricted (default). Memory of prefixes
can content 1 digit only. If you insert 1 digit only the Link Gate A Premium will check first position only.
Rewriting of memory by storing of new fix numbers are old fix-numbers erased.
Erasing of memory - Memory you will erase by storing of „nothing“. You dial only number of memory which you want
erase and confirm it.
22 Very important features is acknowledge character setting. Default is #. When is # used for PBX features you can
change it on *.