© 01/13 REV 01/19 Power Gear 3010001344 Rev. 0E
M²-Sync Room
Slideout System
Owners Manual
Introduction
SYSTEM DESCRIPTION
Your Power Gear Slideout System is a rack and pinion design operated by a pair of
12 Volt DC electric motors.
MAJOR COMPONENTS
· Inner rail assemblies are designed to support the room weight.
· The 12 Volt DC gearmotor will operate the room using power from the battery.
· Slideout systems are equipped with a manual override that allows you to extend
/ retract the room in the event of a loss of power.
· A specially designed control that gives the user full control of room movement, in
or out. The control has programmable stops that stop the motor when the room
is fully extended or retracted and the ability to detect faults for ease in
troubleshooting.
Your Power Gear slide-out system has been designed to require very little
maintenance. To ensure the long life of your slide-out system read and follow these
few simple procedures.

excess build-up of dirt or other foreign material; remove any debris or items that
may be present.

of silicone spray or lithium grease to the roller and bearing sleeve I.D., removing
any excess lubricant so that dirt or debris do not build-up. DO NOT lubricate the
slide-out drive gears, gear racks, or roller OD as this will attract dirt / debris.
IF YOU HAVE ANY PROBLEMS OR QUESTIONS CONSULT YOUR LOCAL
AUTHORIZED DEALER.
Do not work on your slide
out system unless the
battery is disconnected
Owners Manual
M² - Sync Room Slideout System: for
slideout control boxes 1510000122,
1510000143 and 1510000198
CONTENTS
1
1
2
3
4
6
Introduction
Preventative Maintenance
Operation Mode
Fault Diagnostics
Troubleshooting
Override Modes
Preventative Maintenance
CAUTION
!
PRODUCTS
CO
NT
EN
TS
CCD-0002533
Question and Answer IconNeed help?

Do you have a question about the Lippert Components Power Gear M2-Sync and is the answer not in the manual?

Lippert Components Power Gear M2-Sync Specifications

General IconGeneral
BrandLippert Components
ModelPower Gear M2-Sync
CategoryControl Unit
LanguageEnglish

Summary

Introduction to Slideout System

System Description

Overview of the rack and pinion slideout system operated by 12 Volt DC electric motors.

Major Components of Slideout

Details inner rail assemblies and the 12 Volt DC gearmotor for room operation and manual override.

Preventative Maintenance for Slideout

Slideout Operation Modes

Extending the Room

Step-by-step guide to extend the slideout room, including pre-operation checks.

Retracting the Room

Step-by-step guide to retract the slideout room, including pre-operation checks.

Slideout Fault Diagnostics

Troubleshooting Guide for Touch Pad A

Troubleshooting Guide for Touch Pad B

Slideout Override Modes

Emergency Retract Mode

Procedure to manually retract the room when the system loses power or has a fault.

Emergency Retract Module (ERM)

Describes an optional module for bypassing the control for emergency retraction.

Manual Crank Mode

Outlines the procedure for manually cranking the slideout room when other methods fail.

Additional Reference Documents for Slideout System