Winterizing
If water is allowed to freeze in the system, damage to the
plumbing and pump may occur. To protect against damage
from freezing, completely drain the tank, pump and
plumbing and perform winterizing tasks.
NOTE: 
toxic antifreeze for potable water is safe for use in the
pump.
DO NOT USE AUTOMOTIVE ANTIFREEZE TO
WINTERIZE POTABLE WATER SYSTEMS. SUCH
SOLUTIONS ARE HIGHLY TOXIC. INGESTION MAY
CAUSE SERIOUS INJURY OR DEATH.
1. Drain the water tank.
NOTE: 
faucets while allowing the pump to operate (15 minutes
󰀨
2. Open all the faucets, including the lowest valve or drain
in the plumbing, and allow the pump to purge the water
󰀨
3. Using a pan to catch the remaining water, remove the

4. Turn the pump on, allowing it to operate until the water is
expelled.
5. 󰀨
the pump. Do not reconnect the hoses to the pump.
6. 

7. Leave all faucets open to guard against damage.
NOTE: Sanitize the plumbing system before putting it back
into service. See Sanitizing section.