1
ALPHA Series
NEW ALPHA Series
LPW/LPWS Engine
Operators' Handbook
P027-08270

Table of Contents

Questions and Answers

  • R
    rebecca10Aug 16, 2025
    Why is my Lister Petter NEW ALPHA LPWS4 difficult to start?
    • R
      Rickey TranAug 16, 2025
      If your Lister Petter Engine is hard to start or won't start at all, several factors could be at play. Ensure you're using the correct starting procedure. The issue might stem from unsuitable lubricating oil or fuel. Check if there's fuel in the tank and whether the fuel filter is clogged; if so, refill the tank, prime the fuel system, or replace the filter. Air or water/dirt in the fuel system can also cause this; prime or flush the fuel system accordingly. Other potential causes include a faulty injector or pump (replace or service), a discharged battery or poor connections (recharge/replace battery, tighten terminals), or a fuel control solenoid not energised (check electrical system shutdown devices).
  • K
    Kevin TurnerAug 19, 2025
    What to do if Lister Petter NEW ALPHA LPWS4 Engine battery will not charge?
    • D
      doylejoseSep 12, 2025
      If the battery of your Lister Petter Engine isn't charging, check for loose or corroded connections and clean and tighten them. A worn-out battery won't hold a charge, so replace it. Also, inspect the alternator drive belt and replace or re-tension it if it's loose.
  • Y
    yharveyAug 22, 2025
    What to do if my Lister Petter NEW ALPHA LPWS4 Engine stops suddenly?
    • K
      Kevin HaynesAug 22, 2025
      If your Lister Petter Engine suddenly stops, several issues could be the cause. Check for a lack of fuel and refill the tank if necessary. Air or water in the fuel system can also cause the engine to stop; in this case, prime or drain, flush, refill, and prime the fuel system. A choked fuel or air filter can also be the culprit; replace the fuel filter or clean the air filter. Other potential causes include overload (reduce the load), overheating, loss of compression (check piston rings and valves), loss of electrical supply to the fuel pump solenoid (check the electrical feed), or automatic shutdown due to protective devices (investigate and rectify the cause).
  • A
    allison60Aug 25, 2025
    Why is my Lister Petter NEW ALPHA LPWS4 Engine losing power?
    • R
      Rhonda MillerAug 26, 2025
      If your Lister Petter Engine lacks power, several factors could be responsible. Loss of compression might be the cause, so check the piston rings and valves. A choked air filter can restrict airflow, so dismantle and clean the cap and element. Poor quality fuel can also lead to power loss, so drain, flush, refill, and prime the fuel system. Additionally, check for a choked exhaust system (dismantle and clean), overload (reduce the load), or a choked fuel filter (replace the filter). In some cases, a worn engine may be the reason, requiring a major overhaul.
  • R
    Rhonda VelasquezAug 28, 2025
    How to fix overheating in my Lister Petter NEW ALPHA LPWS4 Engine?
    • D
      David IbarraAug 28, 2025
      If your Lister Petter Engine is overheating, several factors could be the cause. Check if the radiator fan belt is too slack and adjust the belt tension. An overload can also lead to overheating, so reduce the load. Ensure the lubricating oil level is adequate by refilling the sump if it's too low. Recirculation of exhaust gases or cooling air can also cause overheating, requiring a redesign of the exhaust and ventilation system. Clean any obstructions from the radiator cooling fins. Also, check the coolant level for leaks and refill if necessary. Finally, an obstructed cooling system can cause overheating; drain, flush, and refill the system.
  • J
    Jenny WadeAug 31, 2025
    Why is the speed of my Lister Petter NEW ALPHA LPWS4 unstable?
    • D
      David JohnsAug 31, 2025
      If your Lister Petter Engine has an unstable speed, it could be due to several reasons. Poor quality fuel can cause this issue, so drain, flush, refill, and prime the fuel system. A fuel system restriction, often due to a clogged fuel filter, can also lead to unstable speed; replace the fuel filter. Similarly, a restriction in the induction system, such as a dirty air cleaner element, can cause this problem; replace the air cleaner element. Lastly, a fault in the fuel lift pump can result in unstable engine speed; replace the diaphragm and/or pump.
  • J
    Johnny DiazSep 3, 2025
    Why does the starter motor of my Lister Petter NEW ALPHA LPWS4 not operate?
    • K
      Katelyn JacobsSep 3, 2025
      If the starter motor on your Lister Petter Engine isn't working, begin by checking for loose or corroded connections and clean and tighten them. If the battery is worn out, replace it. Also, inspect the starter panel and its connections; adjust the connections and/or replace the panel if faulty.
  • F
    fmeadowsSep 6, 2025
    What causes undercharging in my Lister Petter NEW ALPHA LPWS4 Engine?
    • K
      kimberlyhernandezSep 6, 2025
      If your Lister Petter Engine is undercharging, it could be due to several reasons. Excessive electrical load from added accessories can cause this, so remove accessories or fit a higher output alternator. Poor electrical connections to the alternator or battery can also lead to undercharging; inspect, clean, and rectify the cause. A faulty battery may not hold a charge properly; test and recharge or replace it. Lastly, a faulty alternator can also be the culprit; test and replace it if necessary.
  • J
    Jennifer PhillipsSep 9, 2025
    Why does my Lister Petter NEW ALPHA LPWS4 Engine battery require excessive amounts of water?
    • L
      lbakerSep 9, 2025
      If your Lister Petter Engine's battery needs excessive water, it may be due to a leaking battery case; clean the surrounding area and replace the battery. A defective battery can also cause this issue; test or replace the battery. Additionally, a battery charging rate that's too high can lead to excessive water consumption; check the alternator output and battery charging system.
  • H
    hernandezashleySep 12, 2025
    What causes overcharging in a Lister Petter NEW ALPHA LPWS4?
    • P
      Pamela CamposSep 12, 2025
      If your Lister Petter Engine is overcharging, the most likely cause is a faulty alternator. Test the alternator and replace it if necessary.

Summary

Safety Information

General Engine Safety Precautions

Essential safety guidelines for operating and servicing the engine, covering general and emergency precautions.

Personal Safety Guidelines

Measures for personal protection, including appropriate clothing and avoiding contact with moving engine parts.

Chemical Handling Safety

Safety procedures for handling hazardous chemicals such as fuel, oil, coolant, and battery acid.

Fuel System Safety Precautions

Specific warnings and safety measures for the engine's fuel system, including high-pressure fluid hazards.

Filter and Element Handling Safety

Precautions for handling and disposing of used and new oil and fuel filter elements.

Oil Seal Material Safety

Warnings regarding potential corrosive acid from Viton oil seals at high temperatures.

Battery Safety Precautions

Critical safety measures for handling batteries, including risks from sulfuric acid and explosive gases.

Electrical System Safety

Safety guidelines for electrical systems, wiring cables, and alternator connections to prevent damage.

Pre-Start Safety Checks

Mandatory checks and procedures to ensure engine safety before attempting to start.

Engine Lifting Safety

Important safety instructions for lifting the engine using designated lifting eyes and equipment.

Pre-Maintenance Safety Procedures

Steps to ensure a safe working environment and procedures before commencing any engine maintenance.

Starting and Stopping

Key Start Operation Procedures

Step-by-step instructions for starting various LPW/LPWS engine models using the key start system.

Troubleshooting Engine Failure to Start

Guidance on what to do if the engine fails to start within the recommended cranking time.

Engine Stopping Procedures

Safe methods for stopping all engine models, including specific considerations for LPWT4 engines.

Engine Fluids

Routine Maintenance

Pre-Maintenance Checks

Essential checks to perform before starting any maintenance work on the engine.

Troubleshooting Engine Problems

Warranty Information

Lister Petter NEW ALPHA LPWS4 Specifications

General IconGeneral
Engine ModelLPWS4
Number of Cylinders4
Bore86 mm
Stroke80 mm
Fuel TypeDiesel
Cooling SystemWater-cooled
Fuel SystemIndirect injection
Compression Ratio22:1
AspirationNaturally Aspirated
Engine Type4-stroke, water-cooled diesel engine
Lubrication SystemForced feed