WARNING

Questions and Answers

  • C
    Catherine PetersAug 9, 2025
    What to do if the burner does not stay lit on my LOCO COOKERS Boiler?
    • H
      hannahaliAug 9, 2025
      If the burner on your LOCO COOKERS Boiler doesn't stay lit, it could be due to: * **Excessive wind:** Move the appliance to a location where high wind is not a factor and relight the burner once the appliance is cool. * **Empty LP tank:** Refill the LP tank at an authorized dealer or purchase a new filled LP tank.
  • C
    Connie WellsAug 18, 2025
    How to increase water temperature in LOCO COOKERS Boiler?
    • J
      James ChavezAug 19, 2025
      If the water in your LOCO COOKERS Boiler isn't reaching the desired cooking temperature: * Ensure the regulator control knob is fully opened by rotating it in a clockwise direction. * If the Overfill Protection Device (OPD) on the LP tank has been activated, reset it by turning the regulator control knob and the LP tank valve OFF. Disconnect the regulator from the LP tank and wait at least one minute. Reconnect the regulator to the LP tank and fully open the LP tank valve.
  • H
    hoffmannatalieOct 28, 2025
    Why won't the burner light on my LOCO COOKERS Boiler?
    • J
      Justin EricksonOct 29, 2025
      If the burner on your LOCO COOKERS Boiler won't light, there are several potential causes: * **Bad connection:** Ensure the regulator coupling nut is fully tightened on the LP tank valve. * **Empty LP tank:** Refill the LP tank at an authorized dealer or purchase a new filled LP tank. * **Incorrect ignition:** Press and hold the ignition button until the burner lights. * **Battery issues:** * Make sure the + and – ends of the battery are oriented properly, with the + end toward the battery cap. * Unscrew and reinstall the battery cap, ensuring the threads are aligned and fully engaged. * Replace a weak or dead battery with a new alkaline AA battery. * **Wiring problems:** Check and reconnect any loose electrode/igniter wires. For broken or damaged wires, contac...

Summary

Warnings and Safety Precautions

Parts Diagram

Parts and Hardware

Component Inventory List

Detailed list of all product components and their quantities.

Assembly Hardware Specifications

List of screws, nuts, and other fasteners required for assembly.

Assembly Instructions

Initial Frame and Heat Shield Assembly

Assemble the main frame structure and attach initial heat shields.

Wheel and Bracket Installation

Attach wheels and burner mounting brackets to the frame.

Regulator and Cover Plate Mounting

Mount the regulator and cover plate, feeding the hose through the panel.

Ignitor and Wire Management

Install the ignitor assembly and secure wiring with tie wire.

Heat Shield Mounting

Install upper heat shields using mounting brackets and screws.

Panel and Bottle Opener Installation

Attach upper panels and the bottle opener.

Lid and Handle Assembly

Install lid supports and basket handles on the boiler.

Basket and Cart Handle Attachment

Attach basket handles and cart handles to the unit.

Final Handle and Feature Assembly

Attach cart handles and prepare for boiler features.

Boiler Features and Ignitor Battery

Install ignitor battery and review key boiler features.

Operating Instructions

Connecting Regulator to LP Tank

Guide for securely connecting the regulator and LP tank for operation.

Leak Testing and Safety Checks

Procedures for testing gas connections and ensuring safe operation.

Lighting and Burner Operation

Instructions for lighting the burner, flame checks, and shutdown.

Boiler Safety and Shutdown

Procedures for burner flame checks, accidental extinguishment, and safe shutdown.

Disconnecting Regulator and Boiler Prep

Steps for safely disconnecting the regulator and preparing the boiler.

Adding Water and Seasoning

Guidelines for filling the boiler with water and adding seasonings.

Boiling Food and Cooking Times

Instructions for boiling food, including timings for crawfish, crab, and shrimp.

Care and Maintenance

Pre-Use and General Cleaning

Steps for initial checks, cleaning food contact parts, and handling soot.

Burner and Tube Maintenance

Procedures for cleaning the burner, burner tubes, and checking for obstructions.

Safety Precautions During Maintenance

Important cautions and dangers to observe during cleaning and maintenance.

Troubleshooting Guide

Burner Ignition Issues

Solutions for when the burner fails to light or stay lit.

Temperature and Performance Issues

Troubleshooting steps for when the water does not reach the desired cooking temperature.