11
2). Electric Starting
Move the fuel valve lever to the ON position.
Set the engine speed lever at START Position.
Turn the starting key to “START”.
Remove your hand from the key as soon as the engine starts.
If the starting motor doesn’t start after 10 seconds, wait a while(for about 15 seconds)
before attempting to start again.
When the engine is difficult to start in cold weather, Press the heater button for about 10-20
seconds and then release, you can easily start the engine.
If the starting motor is turned for too long, the battery will go flat and the motor
will seize up.
When the engine is stopped , the starting key switch is turned clockwise to the “ON”
position, then the oil pressure Indicator light is on.
When the engine is running , the start switch key stop in the “ON” position, the oil
pressure indicator light goes out, if the light stays lit, you should stop to check the
oil level.
Starting switch key
Heater button
Indicator light