the power supply is no less than 45
0
C, the fan start to work, while the
temperature is less than 45
0
C, the fan stop working.
3. The protective ground terminal of the tree-core power cord should be
reliably connected with the ground to ensure safety in use and reduce the
ripple.
4. Do not start the power supply with load, otherwise it easily damage the
power supply and load. When the load current is more than 10A, please
choose the back output terminal, tighten the output terminal to avoid
damaging the terminal which caused by large contact resistance. Please
regularly check the connecting terminal whether it is loose or not.
5. Over temperature protection: The power supply has over temperature
protection function. When inside temperature is higher than protection value,
the power supply will stop working. After the inside temperature is lower than
protection value, the power supply will come to work again. Do not use the
power supply in the condition that the temperature is higher than 40
0
C. There
should be enough space for heat dissipation.
6. This serial is a kind of switch power supply. It has the function of about 2
seconds with time delay start-up (turn on the power supply, after about 2
seconds, the indicator light is on and the LED has display). Also it has the
function of about 1-5 seconds with time delay start-down.