Loop-O9500 SDH/SONET IMAP
Initial Insulation Resistance
Min. 100M ohm (at 500Vdc)
Maximum switching voltage
Local loopback, payload loopback, line loopback
Direction: to optical lines
Local loopback, payload loopback, line loopback:
Direction: to optical lines
Local loopback, line loopback:
Direction: to optical lines, to tributary lines
Local and remote loopbacks
To optical direction or backplane direction
Performance Parameters: Error Block (EB), Background Block Error (BBE), Error Second(ES),
Burst Error Second (BES), Severe Error Second (SES), Unavailable Second(UAS)
Alarm History
Alarm History
Alarm Cut Off, Power Loss/Uneqp, Fan Fail, Fan Module Uneqp,
Overheat, TS Sync Loss, Logon and Logout, Optical Port Uneqp, Card In,
Card Out, Card Type Mismatch, Card Port Number Mismatch, Card Fail,
Card Registration, SNCP Switch, MSP Switch, Trib Protection Sync,
Standby
XCU Takeover, Standby Trib Takeover, XCU Sync, SFP Tx Fail, SFP Rx
Fail,
SFP Temperature, LS Protection, LS ID Mismatch
PI-LOS RS-LOF RS-TIM MS-SD MS-SF MS-AIS
MS-RDI MS-REI B1-BIP B2-BIP
AU-LOP AU-AIS HP-SD HP-SF HP-UNEQ HP-PLM
HP-TIM HP-RED-P HP-RDI-S HP-RDI-C HP-LOM
HP-REI
TU-LOP TU-AIS LP-SD LP-SF LP-UNEQ LP-PLM
LP-TIM LP-RDI-P LP-RDI-S LP-RDI-C LP-REI
LP-BIP
LOS-PI, LOF-S, TIM-S, SD-L , SF-L ,
AIS-L , RDI-L , REI-L UAS, B1-BIP, B2-BIP
LOP-P, AIS-P, SD-P, SF-P, UNEQ-P, PLM-P,
TIM-P, RDI-P-P, RDI-S-P, RDI-C-P, RDI-P-P,
LOM-P, REI-P, B3-BIP-P
LOP-V, AIS-V, SD-V, SF-V, UNEQ-V, PLM-V, TIM-V,
RDI-P-V, RDI-S-V, RDI-C-V, REI-V, BIP-V
Contains up to 300 alarm records of latest alarm types, alarm severity, date, and time.