Do you have a question about the Lorentz PowerPack PP600H AC and is the answer not in the manual?
Brand | Lorentz |
---|---|
Model | PowerPack PP600H AC |
Category | Media Converter |
Language | English |
Solar pumps may not provide sufficient flow under all conditions, especially in unusually cloudy weather or when sufficient storage cannot be provided.
The PowerPack allows the pump to be powered by an AC generator or mains supply, acting as a changeover switch.
Mount the PowerPack close to the pump controller in a vertical position, protected from direct rainfall.
All wires must be #14 AWG (2.5 mm²) or larger for connections.
Select AC input voltage by connecting terminal 1 to either 2 (120VAC) or 3 (240VAC).
Bond the metal enclosure to the ground connections of the AC power source and the solar power system.
Install a 15A circuit breaker at the power source or distribution box for the AC input.
Connect AC power to terminals L and N. For 240V, N does NOT indicate neutral.
Connect the + and - wires from the solar array disconnect switch to the SOLAR POWER IN terminals.
Connect two wires from the DC POWER OUT + and - terminals to the POWER IN + and - terminals in the solar pump controller.
Connect AC source, turn on Power Pack after connecting to pump controller for system start.
Turning PowerPack OFF or disconnecting AC source leaves solar connected; pump may restart in 2 minutes.
Turn OFF PowerPack or AC supply when not needed to prevent constant power draw.
After turning PowerPack OFF, it takes up to 50 seconds for the POWER ON LED to extinguish.