EasyManua.ls Logo

Lowara GTKS20 - User Manual

Lowara GTKS20
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cod. 001073617 rev.L ed. 03/2016
GRUPPI PRESSIONE 2 POMPE
Istruzioni d’installazione e d’uso
it
2-PUMP BOOSTER SETS
Installation and operating instructions
en
GROUPES DE SURPRESSION
AVEC 2 POMPES
Notice pour l’installation et l’emploi
fr
DRUCKSTEIGERUNGSANLAGE
MIT 2 PUMPEN
Montage- und Betriebsanleitung
de
GRUPO DE PRESIÒN 2 BOMBAS
Instrucciones para la instalación y el uso
es
UNIDADE DE PRESSURIZAÇÃO
2 BOMBAS
Instruções instalação e uso
pt
DRUKVERHOGINGSGROEPEN
MET 2 POMPEN
nl
Aanwijzingen voor de installatie
en het gebruik
2-PUMPPUISET PAINEYKSIKÖT
Asennus- ja käyttöohjeet
fi
2-насосные установки для
повышения давления
Инструкции по монтажу
и эксплуатации
ru
Applica qui l’adesivo col codice a barre
Apply the bar code label here

Table of Contents

Questions and Answers

  • C
    castroderrickAug 2, 2025
    Why Lowara GTKS20 Extender motor runs but no water is delivered?
    • M
      Michelle WalkerAug 2, 2025
      If the Lowara Extender motor runs but no water comes out, there might be several reasons. First, ensure there is water available on the suction side and inside the pump by filling the pump or suction piping and opening any on-off valves. Second, check for air in the suction piping or pump and bleed the pump, inspecting the suction connections. Also, verify that there is no loss of pressure on the suction side, checking the NPSH and modifying the system if needed. Furthermore, inspect the check valve to ensure it is not jammed and clean it if necessary. Clear any clogs in the pipe. Finally, for three-phase motors, confirm the rotation is correct and change the direction of rotation if it's not.
  • A
    aevansAug 6, 2025
    What to do if Lowara GTKS20 motor does not start?
    • D
      diazjessicaAug 6, 2025
      If the Lowara Extender motor isn't starting, first ensure the power supply is properly connected. If that's not the issue, check for triggering of the motor protector and eliminate any malfunctions. For single-phase motors, the motor thermal protector may have triggered; wait for it to reset automatically. For three-phase motors, check the automatic switch in the electric panel and reset it if necessary. Finally, if none of these steps work, the motor itself may be defective and require repair or replacement.
  • A
    Angel PalmerAug 11, 2025
    How to fix frequent startups and stops of Lowara Extender?
    • J
      jill65Aug 11, 2025
      Frequent startups and stops of the Lowara Extender can be caused by a defective tank, which would require repair or replacement. Another potential cause is an incorrect pressure switch adjustment. To resolve this, increase the differential pressure or the stop pressure.
  • J
    Jerry SweeneyAug 15, 2025
    What to do if Lowara Extender pump leaks water?
    • D
      david44Aug 15, 2025
      If the Lowara Extender pump is leaking water, it could be due to a defective mechanical seal, which would need to be replaced. Another possible cause is undue mechanical stress on the pump. In this case, ensure that the pipes are properly supported.
  • A
    Annette RoseAug 19, 2025
    Why Lowara Extender motor starts then stops immediately?
    • R
      robertmartinezAug 19, 2025
      If the Lowara Extender motor starts briefly and then stops, it might be due to an incorrect tank precharge pressure; check the tank precharge. Another possible cause is an incorrect pressure switch adjustment. To fix this, increase the differential pressure or the stop pressure.
  • J
    Jessica SandersAug 25, 2025
    Why is my Lowara GTKS20 Extender too noisy?
    • W
      William WolfAug 25, 2025
      Excessive noise in the Lowara Extender could be due to water return when pumps stop; check the check valve. Cavitation could also be the cause; check the suction. Finally, the pump rotation may be hindered; check for undue mechanical stress on the pump.
  • J
    Jessica Simon DVMAug 28, 2025
    How to troubleshoot Lowara Extender set if it is off?
    • P
      Philip BrownAug 28, 2025
      If the Lowara Extender set is off, first check if the power supply is disconnected and connect it. If the issue persists, the fuse may be blown; replace it.

Summary

General Safety Warnings

Critical Safety Instructions

Mandatory safety precautions during installation and operation, covering electrical and pressure hazards.

Product Overview

Operating Limits

Details on acceptable fluid temperature, ambient temperature, and operating pressure ranges.

Product Description

Detailed description of the booster set's components and configuration.

Pump Operation

Explanation of how pumps start and stop based on system pressure and demand.

Control Panel Features

Installation Guide

Piping, Tank, and Air Feeder

Guidance on pipe sizing, tank selection, volume calculation, and air feeder connection.

Protection Systems Setup

Setup and configuration of dry running and maximum pressure protection systems.

Electrical Connections

Mandatory requirements and safety measures for electrical connections.

System Settings

Motor Protection Settings

Details on motor overload protection for single and three-phase units.

Pressure Switch Settings

Setting and adjustment procedures for pressure switches and differential pressure.

Electronic Control Card

Startup Procedure

Step-by-step instructions for initial startup of the booster set.

Modifying Settings Post-Startup

Steps to modify settings like pressure activation and deactivation values after startup.

Maintenance and Components

Repair and Spare Parts

Guidelines for equipment repairs using original spare parts.

Troubleshooting Common Issues

Disposal and Specifications

Lowara GTKS20 Specifications

General IconGeneral
TypeExtender
ModelGTKS20
MaterialStainless Steel
Inlet Connection1"
Outlet Connection1"